SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 37 331 Measured va lue outside tol. (Error c ode 21H) CAUSE ● Error durin g course of me asurement …

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 36
325 Measure ranges exceeded (Error code 1BH)
CAUSE
●
Setpoint specified is incorrect; incorrect component at the nozzle; mismeasurement (jaws dirty)
REMEDY
●
Check data record for CRDL test in the component description in the line computer and correct if
necessary; check components; clean jaws.
326 Measured value outside tol. (Error code 1CH)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
327 Measured value outside tol. (Error code 1DH)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
328 Measured value outside tol. (Error code 1EH)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
329 Measured value outside tol. (Error code 1FH)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
330 Measured value outside tol. (Error code 20H)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 37
331 Measured value outside tol. (Error code 21H)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
332 Measured value outside tol. (Error code 22H)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
333 Phase error during CRDL measurement (Error code 23H)
CAUSE
●
Incorrect component part at the nozzle; angle of the phase shift outside tolerance.
REMEDY
●
Check component supply, set-up.
334 Measured value outside tol. (Error code 24H)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
335 Measured value outside tol. (Error code 25H)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
336 Measured value outside tol. (Error code 26H)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 38
337 Measured value outside tol. (Error code 27H)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
338 Measured value outside tol. (Error code 28H)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
339 Measured value outside tol. (Error code 29H)
CAUSE
●
Component incorrect.
REMEDY
●
Check set-up.
340 Wrong diode polarity, check feeder (2AH)
CAUSE
●
Diode positioned incorrectly polarized between the measuring jaws.
REMEDY
●
341 Tantalum capacitor pol. not detected (2BH)
CAUSE
●
Component incorrect.
REMEDY
●
Check set-up.
342 Wrong tantal C pol., check feeder (2CH)
CAUSE
●
Capacitor positioned incorrectly polarized between the measuring jaws.
REMEDY
●
Not necessary since positioning corrected automatically.