SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 37
331 Measured value outside tol. (Error code 21H)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
332 Measured value outside tol. (Error code 22H)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
333 Phase error during CRDL measurement (Error code 23H)
CAUSE
●
Incorrect component part at the nozzle; angle of the phase shift outside tolerance.
REMEDY
●
Check component supply, set-up.
334 Measured value outside tol. (Error code 24H)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
335 Measured value outside tol. (Error code 25H)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
336 Measured value outside tol. (Error code 26H)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 38
337 Measured value outside tol. (Error code 27H)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
338 Measured value outside tol. (Error code 28H)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
339 Measured value outside tol. (Error code 29H)
CAUSE
●
Component incorrect.
REMEDY
●
Check set-up.
340 Wrong diode polarity, check feeder (2AH)
CAUSE
●
Diode positioned incorrectly polarized between the measuring jaws.
REMEDY
●
341 Tantalum capacitor pol. not detected (2BH)
CAUSE
●
Component incorrect.
REMEDY
●
Check set-up.
342 Wrong tantal C pol., check feeder (2CH)
CAUSE
●
Capacitor positioned incorrectly polarized between the measuring jaws.
REMEDY
●
Not necessary since positioning corrected automatically.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 39
343 Measured value outside tol. (Error code 2DH)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
344 Measured value outside tol. (Error code 2EH)
CAUSE
●
Error during course of measurement in the tester.
REMEDY
●
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
345 Calibration value is out of range (Error code 2FH)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
346 Calibration value is out of range (Error code 30H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
347 Calibration value is out of range (Error code 31H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
348 Calibration value is out of range (Error code 32H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
349 Calibration value is out of range (Error code 33H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.