SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 39 343 Measured va lue outside tol. (Error c ode 2DH) CAUSE ● Error durin g course of me asurement …

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 38
337 Measured value outside tol. (Error code 27H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
338 Measured value outside tol. (Error code 28H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
339 Measured value outside tol. (Error code 29H)
CAUSE
Component incorrect.
REMEDY
Check set-up.
340 Wrong diode polarity, check feeder (2AH)
CAUSE
Diode positioned incorrectly polarized between the measuring jaws.
REMEDY
341 Tantalum capacitor pol. not detected (2BH)
CAUSE
Component incorrect.
REMEDY
Check set-up.
342 Wrong tantal C pol., check feeder (2CH)
CAUSE
Capacitor positioned incorrectly polarized between the measuring jaws.
REMEDY
Not necessary since positioning corrected automatically.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 39
343 Measured value outside tol. (Error code 2DH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
344 Measured value outside tol. (Error code 2EH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
345 Calibration value is out of range (Error code 2FH)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
346 Calibration value is out of range (Error code 30H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
347 Calibration value is out of range (Error code 31H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
348 Calibration value is out of range (Error code 32H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
349 Calibration value is out of range (Error code 33H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 40
350 Calibration value is out of range (Error code 34H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
351 Calibration value is out of range (Error code 35H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
352 Calibration value is out of range (Error code 36H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
353 Calibration value is out of range (Error code 37H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
354 Calibration value is out of range (Error code 38H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
355 Calibration value is out of range (Error code 39H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
356 Calibration value is out of range (Error code 3AH)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.