SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 43 371 Calibration value is out of range (Er ror code 49H) CAUSE ● Error d uring the c ourse of ca …

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 42
364 Calibration value is out of range (Error code 42H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
365 Calibration value is out of range (Error code 43H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
366 Calibration value is out of range (Error code 44H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
367 Calibration value is out of range (Error code 45H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
368 Calibration value is out of range (Error code 46H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
369 Calibration value is out of range (Error code 47H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
370 Calibration value is out of range (Error code 48H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 43
371 Calibration value is out of range (Error code 49H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
372 Calibration value is out of range (Error code 4AH)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
373 Calibration value is out of range (Error code 4BH)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
374 Calibration value is out of range (Error code 4CH)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
375 Calibration value is out of range (Error code 4DH)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
376 Calibration value is out of range (Error code 4EH)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
377 Calibration value is out of range (Error code 4FH)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 44
378 Calibration value is out of range (Error code 50H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
379 Calibration value is out of range (Error code 51H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
380 Calibration value is out of range (Error code 52H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
381 Calibration value is out of range (Error code 53H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
382 Calibration value is out of range (Error code 54H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
383 Calibration value is out of range (Error code 55H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
384 BERO SZ1 not released
CAUSE
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
Replace proximity switch, adjust sensing distance; remove component; check toothing for damage;
replace motor with hub, carry out calibration on the motor control board.