00191025-01 - 第632页

SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 45 385 BERO SZ2 not rele ased CAUSE Proximi ty switch d efective; c omponent j ammed betwe en screw…

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 44
378 Calibration value is out of range (Error code 50H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
379 Calibration value is out of range (Error code 51H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
380 Calibration value is out of range (Error code 52H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
381 Calibration value is out of range (Error code 53H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
382 Calibration value is out of range (Error code 54H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
383 Calibration value is out of range (Error code 55H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
384 BERO SZ1 not released
CAUSE
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
Replace proximity switch, adjust sensing distance; remove component; check toothing for damage;
replace motor with hub, carry out calibration on the motor control board.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 45
385 BERO SZ2 not released
CAUSE
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
Replace proximity switch, adjust sensing distance; remove component; check toothing for damage;
replace motor with hub, carry out calibration on the motor control board.
386 Input conveyor occupied
CAUSE
When the belt speed was set there was a PCB board on the input conveyor; sensor defective
REMEDY
Remove the PCB board; fit new sensor.
387 VS: No reaction from M10000 (reset M10000)
CAUSE
M10000 crash; line interruption
REMEDY
Reset M10000; check cable connection.
388 Check sum error in table program
CAUSE
File TISCH.HEX erroneous.
REMEDY
Replace file TISCH.HEX in the station computer.
389 Coplan.: Component will not be processed
CAUSE
Measurement of a component for which no prepare command was sent to the coplanarity module
(error in the cluster and set-up)
REMEDY
Respecify cluster and set-up.
390 Coplan.: Component not loaded
CAUSE
Attempt to measure a component for which no component description was sent to the coplanarity
module.
REMEDY
Check and respecify cluster, set-up and package form data.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 46
391 Coplan.: Row number invalid
CAUSE
Package form description erroneous; software error.
REMEDY
Check and respecify package form description; inform Aut 5 BSM 14 Development.
392 Coplan.: Row number will not be processed
CAUSE
Package form description erroneous; software error.
REMEDY
Check and respecify package form description; inform Aut 5 BSM 14 Development.
393 Number of pins on component not correct
CAUSE
Bent / missing pins; erroneous package form description
REMEDY
Check components charge check; check package form description in the package form editor.
394 Orthogonality error during component meas.
CAUSE
Incorrect or deformed component.
REMEDY
Check components charge check.
395 Dualport RAM of CRDL defective
CAUSE
Hardware error in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
396 Check sum error in CRDL measurement
CAUSE
Transmission error during transmission of machine controller with tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
397 Check sum error in communication with table
CAUSE
Transmission error during transmission of machine controller with component table.
REMEDY
If error keeps recurring, reset station; if resetting does not work, replace component table.