00191025-01 - 第632页
SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 45 385 BERO SZ2 not rele ased CAUSE Proximi ty switch d efective; c omponent j ammed betwe en screw…

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 44
378 Calibration value is out of range (Error code 50H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
379 Calibration value is out of range (Error code 51H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
380 Calibration value is out of range (Error code 52H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
381 Calibration value is out of range (Error code 53H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
382 Calibration value is out of range (Error code 54H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
383 Calibration value is out of range (Error code 55H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
384 BERO SZ1 not released
CAUSE
●
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
●
Replace proximity switch, adjust sensing distance; remove component; check toothing for damage;
replace motor with hub, carry out calibration on the motor control board.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 45
385 BERO SZ2 not released
CAUSE
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
●
Replace proximity switch, adjust sensing distance; remove component; check toothing for damage;
replace motor with hub, carry out calibration on the motor control board.
386 Input conveyor occupied
CAUSE
●
When the belt speed was set there was a PCB board on the input conveyor; sensor defective
REMEDY
●
Remove the PCB board; fit new sensor.
387 VS: No reaction from M10000 (reset M10000)
CAUSE
●
M10000 crash; line interruption
REMEDY
●
Reset M10000; check cable connection.
388 Check sum error in table program
CAUSE
●
File TISCH.HEX erroneous.
REMEDY
●
Replace file TISCH.HEX in the station computer.
389 Coplan.: Component will not be processed
CAUSE
●
Measurement of a component for which no prepare command was sent to the coplanarity module
(error in the cluster and set-up)
REMEDY
●
Respecify cluster and set-up.
390 Coplan.: Component not loaded
CAUSE
●
Attempt to measure a component for which no component description was sent to the coplanarity
module.
REMEDY
●
Check and respecify cluster, set-up and package form data.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 46
391 Coplan.: Row number invalid
CAUSE
●
Package form description erroneous; software error.
REMEDY
●
Check and respecify package form description; inform Aut 5 BSM 14 Development.
392 Coplan.: Row number will not be processed
CAUSE
●
Package form description erroneous; software error.
REMEDY
●
Check and respecify package form description; inform Aut 5 BSM 14 Development.
393 Number of pins on component not correct
CAUSE
●
Bent / missing pins; erroneous package form description
REMEDY
●
Check components charge check; check package form description in the package form editor.
394 Orthogonality error during component meas.
CAUSE
●
Incorrect or deformed component.
REMEDY
●
Check components charge check.
395 Dualport RAM of CRDL defective
CAUSE
●
Hardware error in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
396 Check sum error in CRDL measurement
CAUSE
●
Transmission error during transmission of machine controller with tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
397 Check sum error in communication with table
CAUSE
●
Transmission error during transmission of machine controller with component table.
REMEDY
●
If error keeps recurring, reset station; if resetting does not work, replace component table.