00191025-01 - 第634页
SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 47 398 Coplan.: Row not available CAUSE ● Packa ge form desc ription er roneous; soft ware error. R…

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 46
391 Coplan.: Row number invalid
CAUSE
●
Package form description erroneous; software error.
REMEDY
●
Check and respecify package form description; inform Aut 5 BSM 14 Development.
392 Coplan.: Row number will not be processed
CAUSE
●
Package form description erroneous; software error.
REMEDY
●
Check and respecify package form description; inform Aut 5 BSM 14 Development.
393 Number of pins on component not correct
CAUSE
●
Bent / missing pins; erroneous package form description
REMEDY
●
Check components charge check; check package form description in the package form editor.
394 Orthogonality error during component meas.
CAUSE
●
Incorrect or deformed component.
REMEDY
●
Check components charge check.
395 Dualport RAM of CRDL defective
CAUSE
●
Hardware error in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
396 Check sum error in CRDL measurement
CAUSE
●
Transmission error during transmission of machine controller with tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
397 Check sum error in communication with table
CAUSE
●
Transmission error during transmission of machine controller with component table.
REMEDY
●
If error keeps recurring, reset station; if resetting does not work, replace component table.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 47
398 Coplan.: Row not available
CAUSE
●
Package form description erroneous; software error.
REMEDY
●
Check and respecify package form description; inform Aut 5 BSM 14 Development.
399 Program loss of table or trolley control
CAUSE
●
Battery reserve in the component table is not working.
REMEDY
●
Fit new battery to component table.
400 RAM of trolley control defective
CAUSE
●
Hardware error in the component table
REMEDY
●
If error keeps recurring, reset station; if resetting does not work, replace component table.
401 New nozzle configuration is required
CAUSE
●
New cluster with different nozzle configuration
REMEDY
●
If no nozzle changer is present, apply new nozzle configuration manually to placement head.
402 Pulse is not okay
CAUSE
●
Connection of pulse output to pulse input defective.
REMEDY
●
Check pulse output and pulse input
403 Coplan.: Too many pins measured
CAUSE
●
Measurement erroneous or incorrect component.
REMEDY
●
Repeat measurement.
404 Fault during vacuum measuring in reject position
CAUSE
●
Nozzle worn.
REMEDY
●
Fit new nozzle.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 48
405 Fault during vacuum measuring in reject position
CAUSE
●
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
●
Replace proximity switch, adjust sensing distance; remove component; check toothing for damage;
replace motor with hub, carry out calibration on the motor control board.
406 Axis does not find the correct zero pulse
CAUSE
●
Measurement head incorrectly set
REMEDY
●
Check zero pulse at the measurement head (moving scale) of the longitudinal measurement sys-
tem. Adjust or replace measurement head.
407 Communication with table disturbed
CAUSE
●
Timeout during request to the component table controller.
REMEDY
●
Check cabling.
408 Table has received unknown command
CAUSE
●
Obsolete TISCH.HEX file.
REMEDY
●
Update TISCH.HEX file.
409 Undefined error message
CAUSE
●
Should not occur.
REMEDY
●
410 Telegram to coplanarity too long
CAUSE
●
Package form description of the component includes too much information.
REMEDY
●
Check and respecify package form data; the package form is too large and cannot be processed.