SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 49 411 FM_ERSTER_FEHLER CAUSE ● Error during test ing, sig nific ance vari es. REMEDY ● 412 FM_LETZ…

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 48
405 Fault during vacuum measuring in reject position
CAUSE
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
Replace proximity switch, adjust sensing distance; remove component; check toothing for damage;
replace motor with hub, carry out calibration on the motor control board.
406 Axis does not find the correct zero pulse
CAUSE
Measurement head incorrectly set
REMEDY
Check zero pulse at the measurement head (moving scale) of the longitudinal measurement sys-
tem. Adjust or replace measurement head.
407 Communication with table disturbed
CAUSE
Timeout during request to the component table controller.
REMEDY
Check cabling.
408 Table has received unknown command
CAUSE
Obsolete TISCH.HEX file.
REMEDY
Update TISCH.HEX file.
409 Undefined error message
CAUSE
Should not occur.
REMEDY
410 Telegram to coplanarity too long
CAUSE
Package form description of the component includes too much information.
REMEDY
Check and respecify package form data; the package form is too large and cannot be processed.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 49
411 FM_ERSTER_FEHLER
CAUSE
Error during testing, significance varies.
REMEDY
412 FM_LETZTER_FEHLER
CAUSE
Error during testing, significance varies.
REMEDY
413 FM_FEHLER_1
CAUSE
Error during testing, significance varies.
REMEDY
414 FM_FEHLER_2
CAUSE
Error during testing, significance varies.
REMEDY
415 FM_FEHLER_3
CAUSE
Error during testing, significance varies.
REMEDY
416 FM_FEHLER_4
CAUSE
Error during testing, significance varies.
REMEDY
417 FM_FEHLER_5
CAUSE
Error during testing, significance varies.
REMEDY
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 50
418 FM_FEHLER_6
CAUSE
Error during testing, significance varies.
REMEDY
419 FM_FEHLER_7
CAUSE
Error during testing, significance varies.
REMEDY
420 FM_FEHLER_8
CAUSE
Error during testing, significance varies.
REMEDY
421 FM_FEHLER_9
CAUSE
Error during testing, significance varies.
REMEDY
422 FM_FEHLER_10
CAUSE
Error during testing, significance varies.
REMEDY
423 Position: Evaluation not possible
CAUSE
Component is not positioned properly at the nozzle, or is missing; optical image inadequate.
REMEDY
Change the illumination values and / or the LUT.
424 Dimension: Evaluation not possible
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to provide
measurement result.
REMEDY
Optimize pick-up; check charge (component).