00191025-01 - 第639页

19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 52 431 Colinearity: no res ult CAUSE ● Due to a pr eceding error no result is issued by the visi o…

100%1 / 736
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 51
425 No. of pins: Evaluation not possible
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to provide
measurement result.
REMEDY
Optimize pick-up; check charge (component).
426 Colinearity: Evaluation not possible
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to provide
measurement result.
REMEDY
Optimize pick-up; check charge (component).
427 Spacing: Evaluation not possible
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to provide
measurement result.
REMEDY
Optimize pick-up; check charge (component).
428 Position: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
429 Dimension: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
430 No. of pins: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 52
431 Colinearity: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
432 Spacing: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
433 Position: Component outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
434 Dimension: Comp. outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
435 No. of pins: Comp. outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
436 Colinearity: Cmp. outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
437 Spacing: Component outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 53
438 Undefined error message
CAUSE
Should not occur
REMEDY
439 Undefined error message
CAUSE
Should not occur
REMEDY
440 Undefined error message
CAUSE
Should not occur
REMEDY
441 Undefined error message
CAUSE
Should not occur
REMEDY
442 Undefined error message
CAUSE
Should not occur
REMEDY
443 Coplan.: Measuring data buffer is full
CAUSE
Mismeasurement: component out of focus or measurement interrupted by EMERGENCY STOP.
REMEDY
Repeat measurement; correct focus; do not interrupt with EMERGENCY STOP.
444 Undefined error message
CAUSE
Does not occur
REMEDY