00191025-01 - 第640页

SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 53 438 Undefined er ror message CAUSE ● Should not occu r REMEDY ● 439 Undefined er ror message CAU…

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 52
431 Colinearity: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
432 Spacing: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
433 Position: Component outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
434 Dimension: Comp. outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
435 No. of pins: Comp. outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
436 Colinearity: Cmp. outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
437 Spacing: Component outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 53
438 Undefined error message
CAUSE
Should not occur
REMEDY
439 Undefined error message
CAUSE
Should not occur
REMEDY
440 Undefined error message
CAUSE
Should not occur
REMEDY
441 Undefined error message
CAUSE
Should not occur
REMEDY
442 Undefined error message
CAUSE
Should not occur
REMEDY
443 Coplan.: Measuring data buffer is full
CAUSE
Mismeasurement: component out of focus or measurement interrupted by EMERGENCY STOP.
REMEDY
Repeat measurement; correct focus; do not interrupt with EMERGENCY STOP.
444 Undefined error message
CAUSE
Does not occur
REMEDY
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 54
445 Undefined error message
CAUSE
Does not occur
REMEDY
446 Undefined error message
CAUSE
Does not occur
REMEDY
447 Z axis at IC head cannot be moved upwards
CAUSE
When the start button is pressed the Z axis of the IC head is at bottom and cannot be moved
upwards.
REMEDY
Move Z axis upwards manually; check Z axis IC head.
448 Undefined error message
CAUSE
Should not occur
REMEDY
449 IC head Z axis does not reach placement/pick-up position
CAUSE
Z axis of the IC head stiff; jamming of the IC head not corrected, position cannot be reached.
REMEDY
Inform SMD Service; inspect the jamming; check minimum and maximum travel range.
450 IC head Z axis does not reach 0 position
CAUSE
Z axis of the IC head stiff; jamming of the IC head not corrected; erroneous zero point correction.
REMEDY
Inform SMD Service; inspect the jamming; change zero point correction.