431 Colinearity: no result
CAUSE
●
Due to a preceding error no result is issued by the vision system.
REMEDY
●
See preceding error.
432 Spacing: no result
CAUSE
●
Due to a preceding error no result is issued by the vision system.
REMEDY
●
See preceding error.
433 Position: Component outside of search area
CAUSE
●
Component was not picked up correctly.
REMEDY
●
Check component description and pick-up position.
434 Dimension: Comp. outside of search area
CAUSE
●
Component was not picked up correctly.
REMEDY
●
Check component description and pick-up position.
435 No. of pins: Comp. outside of search area
CAUSE
●
Component was not picked up correctly.
REMEDY
●
Check component description and pick-up position.
436 Colinearity: Cmp. outside of search area
CAUSE
●
Component was not picked up correctly.
REMEDY
●
Check component description and pick-up position.
437 Spacing: Component outside of search area
CAUSE
●
Component was not picked up correctly.
REMEDY
●
Check component description and pick-up position.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 53
438 Undefined error message
CAUSE
●
Should not occur
REMEDY
●
439 Undefined error message
CAUSE
●
Should not occur
REMEDY
●
440 Undefined error message
CAUSE
●
Should not occur
REMEDY
●
441 Undefined error message
CAUSE
●
Should not occur
REMEDY
●
442 Undefined error message
CAUSE
●
Should not occur
REMEDY
●
443 Coplan.: Measuring data buffer is full
CAUSE
●
Mismeasurement: component out of focus or measurement interrupted by EMERGENCY STOP.
REMEDY
●
Repeat measurement; correct focus; do not interrupt with EMERGENCY STOP.
444 Undefined error message
CAUSE
●
Does not occur
REMEDY
●

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 54
445 Undefined error message
CAUSE
●
Does not occur
REMEDY
●
446 Undefined error message
CAUSE
●
Does not occur
REMEDY
●
447 Z axis at IC head cannot be moved upwards
CAUSE
●
When the start button is pressed the Z axis of the IC head is at bottom and cannot be moved
upwards.
REMEDY
●
Move Z axis upwards manually; check Z axis IC head.
448 Undefined error message
CAUSE
●
Should not occur
REMEDY
●
449 IC head Z axis does not reach placement/pick-up position
CAUSE
Z axis of the IC head stiff; jamming of the IC head not corrected, position cannot be reached.
REMEDY
●
Inform SMD Service; inspect the jamming; check minimum and maximum travel range.
450 IC head Z axis does not reach 0 position
CAUSE
●
Z axis of the IC head stiff; jamming of the IC head not corrected; erroneous zero point correction.
REMEDY
●
Inform SMD Service; inspect the jamming; change zero point correction.