00191025-01 - 第641页

19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 54 445 Undefined error me ssage CAUSE ● Does not occur REMEDY ● 446 Undefined error me ssage CAUSE…

100%1 / 736
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 53
438 Undefined error message
CAUSE
Should not occur
REMEDY
439 Undefined error message
CAUSE
Should not occur
REMEDY
440 Undefined error message
CAUSE
Should not occur
REMEDY
441 Undefined error message
CAUSE
Should not occur
REMEDY
442 Undefined error message
CAUSE
Should not occur
REMEDY
443 Coplan.: Measuring data buffer is full
CAUSE
Mismeasurement: component out of focus or measurement interrupted by EMERGENCY STOP.
REMEDY
Repeat measurement; correct focus; do not interrupt with EMERGENCY STOP.
444 Undefined error message
CAUSE
Does not occur
REMEDY
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 54
445 Undefined error message
CAUSE
Does not occur
REMEDY
446 Undefined error message
CAUSE
Does not occur
REMEDY
447 Z axis at IC head cannot be moved upwards
CAUSE
When the start button is pressed the Z axis of the IC head is at bottom and cannot be moved
upwards.
REMEDY
Move Z axis upwards manually; check Z axis IC head.
448 Undefined error message
CAUSE
Should not occur
REMEDY
449 IC head Z axis does not reach placement/pick-up position
CAUSE
Z axis of the IC head stiff; jamming of the IC head not corrected, position cannot be reached.
REMEDY
Inform SMD Service; inspect the jamming; check minimum and maximum travel range.
450 IC head Z axis does not reach 0 position
CAUSE
Z axis of the IC head stiff; jamming of the IC head not corrected; erroneous zero point correction.
REMEDY
Inform SMD Service; inspect the jamming; change zero point correction.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 55
451 IC head sensor for Z axis does not react
CAUSE
Top Bero of the Z axis of the IC head defective; top Bero of the Z axis of the IC head incorrectly
aligned;
erroneous zero point correction.
REMEDY
Check input top Bero (input is always 0); realign top Bero of the Z axis of the IC head; change zero
point correction.
452 IC head sensor for Z axis is not released at top
CAUSE
Top Bero of the Z axis of the IC head defective.
REMEDY
Check input top Bero (input is always 1).
453 Component could not be placed
CAUSE
After placement by the IC head the component is still at the nozzle.
REMEDY
Vacuum circuit defective; forced air or vacuum cannot be switched off.
454 Component could not be placed. Warning!
CAUSE
The component could be recognized as placed by the IC head only after the second measurement.
REMEDY
Check vacuum circuit; check forced air and vacuum of the IC head.
455 Component not on nozzle during placement
CAUSE
After placement by the IC head the component is still at the nozzle.
REMEDY
Vacuum circuit defective; forced air or vacuum cannot be switched off.
456 Component not on nozzle during placement. Warning!
CAUSE
The component could be recognized as placed by the IC head only after the second measurement.
REMEDY
Check vacuum circuit; check forced air and vacuum of the IC head.