00191025-01 - 第642页
SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 55 451 IC head sensor for Z axis does not react CAUSE ● Top Be ro of the Z axis of the I C head def…

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 54
445 Undefined error message
CAUSE
●
Does not occur
REMEDY
●
446 Undefined error message
CAUSE
●
Does not occur
REMEDY
●
447 Z axis at IC head cannot be moved upwards
CAUSE
●
When the start button is pressed the Z axis of the IC head is at bottom and cannot be moved
upwards.
REMEDY
●
Move Z axis upwards manually; check Z axis IC head.
448 Undefined error message
CAUSE
●
Should not occur
REMEDY
●
449 IC head Z axis does not reach placement/pick-up position
CAUSE
Z axis of the IC head stiff; jamming of the IC head not corrected, position cannot be reached.
REMEDY
●
Inform SMD Service; inspect the jamming; check minimum and maximum travel range.
450 IC head Z axis does not reach 0 position
CAUSE
●
Z axis of the IC head stiff; jamming of the IC head not corrected; erroneous zero point correction.
REMEDY
●
Inform SMD Service; inspect the jamming; change zero point correction.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 55
451 IC head sensor for Z axis does not react
CAUSE
●
Top Bero of the Z axis of the IC head defective; top Bero of the Z axis of the IC head incorrectly
aligned;
erroneous zero point correction.
REMEDY
●
Check input top Bero (input is always 0); realign top Bero of the Z axis of the IC head; change zero
point correction.
452 IC head sensor for Z axis is not released at top
CAUSE
●
Top Bero of the Z axis of the IC head defective.
REMEDY
●
Check input top Bero (input is always 1).
453 Component could not be placed
CAUSE
●
After placement by the IC head the component is still at the nozzle.
REMEDY
●
Vacuum circuit defective; forced air or vacuum cannot be switched off.
454 Component could not be placed. Warning!
CAUSE
●
The component could be recognized as placed by the IC head only after the second measurement.
REMEDY
●
Check vacuum circuit; check forced air and vacuum of the IC head.
455 Component not on nozzle during placement
CAUSE
●
After placement by the IC head the component is still at the nozzle.
REMEDY
●
Vacuum circuit defective; forced air or vacuum cannot be switched off.
456 Component not on nozzle during placement. Warning!
CAUSE
●
The component could be recognized as placed by the IC head only after the second measurement.
REMEDY
●
Check vacuum circuit; check forced air and vacuum of the IC head.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 56
457 Undefined error message
CAUSE
●
Does not occur
REMEDY
●
458 Undefined error message
CAUSE
●
Does not occur
REMEDY
●
459 Coplan.: Memory for group description full
CAUSE
●
In the set-up there are too many components with coplanarity measurement.
REMEDY
●
Reduce set-up.
460 Coplan.: Memory for package form description full
CAUSE
●
In the set-up there are too many components with coplanarity measurement.
REMEDY
●
Reduce set-up.
461 Programmed position of D axis outside of travel range
CAUSE
●
Should not occur.
REMEDY
●
Inform AUT 5 BSM 14 Development.
462 Programmed position of Z axis outside of travel range
CAUSE
●
Head height, nozzle length erroneous.
REMEDY
●
Correct head height, nozzle length.
463 IC head D axis does not reach desired position
CAUSE
●
Motor defective; clamping actuated.
REMEDY
●
Fit new motor; release clamping and check.