00191025-01 - 第643页
19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 56 457 Undefined error me ssage CAUSE ● Does not occur REMEDY ● 458 Undefined error me ssage CAUSE…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 55
451 IC head sensor for Z axis does not react
CAUSE
●
Top Bero of the Z axis of the IC head defective; top Bero of the Z axis of the IC head incorrectly
aligned;
erroneous zero point correction.
REMEDY
●
Check input top Bero (input is always 0); realign top Bero of the Z axis of the IC head; change zero
point correction.
452 IC head sensor for Z axis is not released at top
CAUSE
●
Top Bero of the Z axis of the IC head defective.
REMEDY
●
Check input top Bero (input is always 1).
453 Component could not be placed
CAUSE
●
After placement by the IC head the component is still at the nozzle.
REMEDY
●
Vacuum circuit defective; forced air or vacuum cannot be switched off.
454 Component could not be placed. Warning!
CAUSE
●
The component could be recognized as placed by the IC head only after the second measurement.
REMEDY
●
Check vacuum circuit; check forced air and vacuum of the IC head.
455 Component not on nozzle during placement
CAUSE
●
After placement by the IC head the component is still at the nozzle.
REMEDY
●
Vacuum circuit defective; forced air or vacuum cannot be switched off.
456 Component not on nozzle during placement. Warning!
CAUSE
●
The component could be recognized as placed by the IC head only after the second measurement.
REMEDY
●
Check vacuum circuit; check forced air and vacuum of the IC head.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 56
457 Undefined error message
CAUSE
●
Does not occur
REMEDY
●
458 Undefined error message
CAUSE
●
Does not occur
REMEDY
●
459 Coplan.: Memory for group description full
CAUSE
●
In the set-up there are too many components with coplanarity measurement.
REMEDY
●
Reduce set-up.
460 Coplan.: Memory for package form description full
CAUSE
●
In the set-up there are too many components with coplanarity measurement.
REMEDY
●
Reduce set-up.
461 Programmed position of D axis outside of travel range
CAUSE
●
Should not occur.
REMEDY
●
Inform AUT 5 BSM 14 Development.
462 Programmed position of Z axis outside of travel range
CAUSE
●
Head height, nozzle length erroneous.
REMEDY
●
Correct head height, nozzle length.
463 IC head D axis does not reach desired position
CAUSE
●
Motor defective; clamping actuated.
REMEDY
●
Fit new motor; release clamping and check.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 57
464 IC head Z axis does not reach desired position
CAUSE
●
Motor defective; Z axis jamming; clamping actuated.
REMEDY
●
Fit new motor; check Z axis; release clamping and check.
465 IC head D axis disabled
CAUSE
●
D axis switched off at the axis controller switch.
REMEDY
●
Switch on D axis at the axis controller.
466 IC head Z axis disabled
CAUSE
●
Z axis switched off at the axis controller switch.
REMEDY
●
Switch on Z axis at the axis controller.
467 Gantry distance insufficient. Protective system reacted
CAUSE
●
Gantries have been moved too close together.
REMEDY
●
Switch machine off and back on.
468 Component outside of positional tolerance
CAUSE
●
Pick-up not accurate enough; positional tolerances entered in the package form editor are too small.
REMEDY
●
Optimize pick-up; raise positional tolerances in the package form editor.
469 Component outside of positional tolerance
CAUSE
●
Pick-up not accurate enough; positional tolerances entered in the package form editor are too small.
REMEDY
●
Optimize pick-up; raise positional tolerances in the package form editor.
470 Component length outside tolerance
CAUSE
●
Incorrect component length; tolerances defined are too small.
REMEDY
●
Raise tolerance; check component description in the package form editor.