00191025-01 - 第644页

SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 57 464 IC head Z axis does not reach desired positio n CAUSE ● Motor d efective; Z axis jamm ing; c…

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 56
457 Undefined error message
CAUSE
Does not occur
REMEDY
458 Undefined error message
CAUSE
Does not occur
REMEDY
459 Coplan.: Memory for group description full
CAUSE
In the set-up there are too many components with coplanarity measurement.
REMEDY
Reduce set-up.
460 Coplan.: Memory for package form description full
CAUSE
In the set-up there are too many components with coplanarity measurement.
REMEDY
Reduce set-up.
461 Programmed position of D axis outside of travel range
CAUSE
Should not occur.
REMEDY
Inform AUT 5 BSM 14 Development.
462 Programmed position of Z axis outside of travel range
CAUSE
Head height, nozzle length erroneous.
REMEDY
Correct head height, nozzle length.
463 IC head D axis does not reach desired position
CAUSE
Motor defective; clamping actuated.
REMEDY
Fit new motor; release clamping and check.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 57
464 IC head Z axis does not reach desired position
CAUSE
Motor defective; Z axis jamming; clamping actuated.
REMEDY
Fit new motor; check Z axis; release clamping and check.
465 IC head D axis disabled
CAUSE
D axis switched off at the axis controller switch.
REMEDY
Switch on D axis at the axis controller.
466 IC head Z axis disabled
CAUSE
Z axis switched off at the axis controller switch.
REMEDY
Switch on Z axis at the axis controller.
467 Gantry distance insufficient. Protective system reacted
CAUSE
Gantries have been moved too close together.
REMEDY
Switch machine off and back on.
468 Component outside of positional tolerance
CAUSE
Pick-up not accurate enough; positional tolerances entered in the package form editor are too small.
REMEDY
Optimize pick-up; raise positional tolerances in the package form editor.
469 Component outside of positional tolerance
CAUSE
Pick-up not accurate enough; positional tolerances entered in the package form editor are too small.
REMEDY
Optimize pick-up; raise positional tolerances in the package form editor.
470 Component length outside tolerance
CAUSE
Incorrect component length; tolerances defined are too small.
REMEDY
Raise tolerance; check component description in the package form editor.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 58
471 Component width outside tolerance
CAUSE
Incorrect component length; tolerances defined are too small.
REMEDY
Raise tolerance; check component description in the package form editor.
472 VS: Pointer to text table not initialized
CAUSE
Component is not in focus during coplanarity measurement.
REMEDY
Check the focussing during coplanarity measurement; check the IC head z axis clamping
473 Temporary drop in pressure
CAUSE
The compressed air failed during the placement process, the current PCB board is aborted.
REMEDY
Check compressed air feed; check compressed air sensor.
474 Second gantry in travel range
CAUSE
While teaching the fiducials (80S), the operator moved the gantries towards each other.
REMEDY
Move the second gantry out of the travel range of the first gantry.
475 Communication with wafflepack changer faulty
CAUSE
Interface line to the wafflepack changer defective or not correctly connected; power supply to the
wafflepack changer defective.
REMEDY
Check interface cable; check power supply.
476 IC head vacuum of pick-up circle not in valid range
CAUSE
Nozzle dirty; vacuum cannot be switched on; permissible vacuum limit value for open nozzle errone-
ous.
REMEDY
Clean nozzle; check vacuum output and vacuum valve; correct vacuum limit value for open nozzle.