00191025-01 - 第651页
19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 64 511 Error during RMOS Sys tem Call MALLOC CAUSE ● Soft ware e rror REMEDY ● Reboot and inform D…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 63
504 Current limiter I
r.m.s
has reacted
CAUSE
●
Servo is being subjected to limitation, axis jamming.
REMEDY
●
Check mechanism for ease of running.
505 Error during RMOS System Call RECV
CAUSE
●
Software error
REMEDY
●
Reboot and inform Development.
506 Error during RMOS System Call DALOC
CAUSE
●
Software error
REMEDY
●
Reboot and inform Development.
507 Error during RMOS System Call ALOC
CAUSE
●
Software error
REMEDY
●
Reboot and inform Development.
508 Error during RMOS System Call LOOK
CAUSE
●
Software error
REMEDY
●
Reboot and inform Development.
509 Error during RMOS System Call RIO
CAUSE
●
Software error
REMEDY
●
Reboot and inform Development.
510 Error during RMOS System Call CREATEDRIV
CAUSE
●
Software error
REMEDY
●
Reboot and inform Development.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 64
511 Error during RMOS System Call MALLOC
CAUSE
●
Software error
REMEDY
●
Reboot and inform Development.
512 Incorrect value of state counter
CAUSE
●
Software error
REMEDY
●
Reboot
513 Unknown operating state message
CAUSE
●
Software error
REMEDY
●
Reboot
514 Illegal operating state
CAUSE
●
Software error
REMEDY
●
Reboot
515 SV: Unknown data code
CAUSE
●
Software error
REMEDY
●
Inform Development
516 SV: Incorrect data length
CAUSE
●
Software error
REMEDY
●
Inform Development
517 Software error: Answer from coplanarity too long
CAUSE
●
Software error: the answer from coplanarity exceeds the buffer length in the MC
REMEDY
●
Repeat the coplanarity measurement; notify AUT 5 BSM 14 - Development

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 65
518 SV: Unknown message code from other MC
CAUSE
●
Software error
REMEDY
●
Inform Development
519 SV: Unknown message code from station computer
CAUSE
●
Software error
REMEDY
●
Inform Development
520 Unknown data code in MC1 during data exchange
CAUSE
●
Software error
REMEDY
●
If there are problems after this, reset station, inform Development.
521 Software error in SGL Functions
CAUSE
●
Incorrect message to single function (Info1) operator error during transition to single function or fatal
error handling ( start button not pressed )
REMEDY
●
Possibly rebooting
522 Syntax error in command to component table
CAUSE
●
Software error; interface cable reversed.
REMEDY
●
Reboot; connect interface cable correctly.
523 Command not executed, component table not referred
CAUSE
●
Power failure while component carriage moving.
REMEDY
●
Check power supply and Inform SMD Service.
524 Command not executed, component table in refill position
CAUSE
●
Software error
REMEDY
●
Reboot