00191025-01 - 第652页
SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 65 518 SV: Unknown messa ge code from other MC CAUSE ● Softwar e error REMEDY ● Inform Dev elopment…

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 64
511 Error during RMOS System Call MALLOC
CAUSE
●
Software error
REMEDY
●
Reboot and inform Development.
512 Incorrect value of state counter
CAUSE
●
Software error
REMEDY
●
Reboot
513 Unknown operating state message
CAUSE
●
Software error
REMEDY
●
Reboot
514 Illegal operating state
CAUSE
●
Software error
REMEDY
●
Reboot
515 SV: Unknown data code
CAUSE
●
Software error
REMEDY
●
Inform Development
516 SV: Incorrect data length
CAUSE
●
Software error
REMEDY
●
Inform Development
517 Software error: Answer from coplanarity too long
CAUSE
●
Software error: the answer from coplanarity exceeds the buffer length in the MC
REMEDY
●
Repeat the coplanarity measurement; notify AUT 5 BSM 14 - Development

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 65
518 SV: Unknown message code from other MC
CAUSE
●
Software error
REMEDY
●
Inform Development
519 SV: Unknown message code from station computer
CAUSE
●
Software error
REMEDY
●
Inform Development
520 Unknown data code in MC1 during data exchange
CAUSE
●
Software error
REMEDY
●
If there are problems after this, reset station, inform Development.
521 Software error in SGL Functions
CAUSE
●
Incorrect message to single function (Info1) operator error during transition to single function or fatal
error handling ( start button not pressed )
REMEDY
●
Possibly rebooting
522 Syntax error in command to component table
CAUSE
●
Software error; interface cable reversed.
REMEDY
●
Reboot; connect interface cable correctly.
523 Command not executed, component table not referred
CAUSE
●
Power failure while component carriage moving.
REMEDY
●
Check power supply and Inform SMD Service.
524 Command not executed, component table in refill position
CAUSE
●
Software error
REMEDY
●
Reboot

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 66
525 WPC: No tray available.
CAUSE
●
Software error
REMEDY
●
Reboot
526 WPC: Sent set-up contains errors.
CAUSE
●
Software error
REMEDY
●
Reboot
527 Feeder rail of bulk case feeder not installed
CAUSE
●
The feeder rail is not installed on the bulk case feeder
REMEDY
●
Install feeder rail on bulk case feeder
528 Undefined error number of component table (Code 45)
529 Undefined error number of component table (Code 46)
530 Undefined error number of component table (Code 47)
531 Undefined error number of component table (Code 48)
532 Undefined error number of component table (Code 49)
533 Data loss in component table (defective battery)
CAUSE
●
Backup battery flat or defective; Controller A18 defective.
REMEDY
●
Replace battery; fit new A18 and Inform SMD Service.
534 WPC: Fault in feed axis (servo or axis card).
CAUSE
●
Axis board of the feed axis defective; servo of the feed axis defective.
REMEDY
●
Fit new axis board or servo board and inform SMD Service.