00191025-01 - 第660页
SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 73 571 Nozzle not retur ned to <Magazine/garage >: CAUSE ● Garag e indicat ed of the magaz in…

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 72
565 Error during loading of fiducials into MVS
CAUSE
●
Fiducial data from the line computer or station computer disk are erroneous; incorrect MVS Eprom
version
REMEDY
●
Delete fiducial data and teach them again; check MVS Eprom version
566 Error while loading fiducial centering param. into MVS
CAUSE
●
Fiducial data from the line computer or station computer disk are erroneous; incorrect MVS Eprom
version
REMEDY
●
Delete fiducial data and teach them again; check MVS Eprom version
567 Error while loading coplanarity data into module
CAUSE
●
Coplanarity has been selected for BGAs; erroneous GF description in the line computer
REMEDY
●
Deactivate coplanarity option; check GF description
568 Error while loading parameter pool into MVS
CAUSE
●
Erroneous data in the SST.ma file; incorrect MVS Eprom version
REMEDY
●
Check the SST.ma file; check the MVS Eprom version
569 Limited conveyor position recognition
CAUSE
●
Conveyor fiducials are outside the travel range of the main axes
REMEDY
●
Set conveyor up for locations which lie within the travel range of the board camera
570 Nozzle not picked up from <Magazine/garage>:
CAUSE
●
Garage indicated of the magazine in question is already empty; x, y or z positions are not correct
(real.ma)
REMEDY
●
Set magazine full; check the garage in question

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 73
571 Nozzle not returned to <Magazine/garage>:
CAUSE
●
Garage indicated of the magazine in question is already occupied; x, y or z positions are not correct
(real.ma)
REMEDY
●
Nozzle is discarded into rejects tray; check the garage in question
572 Nozzle type not available <Type/for segment>:
CAUSE
●
Nozzle type displayed has not been set up or the corresponding magazine is empty
REMEDY
●
Fill magazine or insert by hand and confirm in the menu
573 Nozzle type not returnable <Type/from segment>:
CAUSE
●
Magazine displayed has not been set up for this nozzle type or the magazine is full
REMEDY
●
Nozzle is discarded into the rejects tray
574 Conveyor position recognition not possible
CAUSE
●
Conveyor fiducials are outside the travel range of the main axes
REMEDY
●
Set up the conveyor for locations which are within the travel range of the board camera
575 Incorrect centering device setting for component concerned
CAUSE
●
Incorrect entry in the line computer GF editor.
REMEDY
●
Change the processing data for the package form in the line computer GF editor.
578 Nozzle not ejected into rejects box
CAUSE
●
The component or the nozzle is jamming at the rejects box.
The rejects box is full.
REMEDY
●
Use the SITEST program to record the x, y and z nozzle positions.
Remove the obstacle or empty the rejects box.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 74
694 Nozzle length deviates excessively from stipulated length
CAUSE
●
No nozzle present.
The nozzle is seated incorrectly.
The wrong nozzle type has been set up.
REMEDY
●
Make sure the head is fitted with the correct nozzle.
Check the seating of the nozzle.
696 Warning: Break to DP1-axis
CAUSE
●
Internal program run error when the DP1 axis is overshooting.
REMEDY
●
Confirm the error message.
If this error occurs frequently, please notify AUT 5 V Service
697 Warning: Break to DP2-axis
CAUSE
●
Internal program run error when the DP1 axis is overshooting.
REMEDY
●
Confirm the error message.
If this error occurs frequently, please notify AUT 5 V Service
698 Error during break to DP1-axis: boot!
CAUSE
●
It is not possible to confirm error message 696 with respect to the internal program run error.
REMEDY
●
Reboot the station. Notify AUT 5 Development.
699 Error during break to DP2-axis: boot!
CAUSE
●
It is not possible to confirm error message 697 with respect to the internal program run error.
REMEDY
●
Reboot the station. Notify AUT 5 Development.
701 BO: Info received is not a message (ident/code)
CAUSE
●
BO has received a message which is not actually classified as a message. The details (ident code)
concern the contents of the message. These values are given in (Info1/Info2).
REMEDY
●
Write down error message giving the complete error message and under what conditions the error
occurred. With the machine at standstill, reset the machine.