19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 78 722 VS: Error du ring memory reque st CAUSE ● Soft ware e rror REMEDY ● Reboot; in form Deve lo…

100%1 / 736
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 77
715 BO: Error in pause (sts)
CAUSE
System error during system call PAUSE.
REMEDY
When the machine is at a standstill, reset the machine.
716 BO Barcode terminator not found
CAUSE
The terminator is missing after the barcode header, barcode at the barcode pen not recognized.
REMEDY
Reread the barcode. If this does not work, check the barcode header and terminator.
717 BO: 1st character of barcode terminator not found
CAUSE
The terminator is missing after the barcode header, barcode at the barcode pen not recognized.
REMEDY
Reread the barcode. If this does not work, check the barcode header and terminator.
718 VS: Unknown message code
CAUSE
Software error
REMEDY
Inform Development; possibly reboot.
719 VS: Error during system call look
CAUSE
Software error
REMEDY
Inform Development; possibly reboot.
720 VS: File could not be opened
CAUSE
File does not exist in the station computer
REMEDY
Reinstall software
721 VS: Error in fiducial data
CAUSE
Fiducial data erroneous; obsolete ICOS version
REMEDY
Reset ICOS, update eproms
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 78
722 VS: Error during memory request
CAUSE
Software error
REMEDY
Reboot; inform Development.
723 VS: File could not be opened
CAUSE
File does not exist in the station computer (TISCH.HEX)
REMEDY
Reinstall software (possibly only TISCH.HEX)
724 VS: Error during memory request
CAUSE
Not enough memory available in the station computer
REMEDY
Reset station computer
725 VS: Error during memory release in VS load
CAUSE
Software error
REMEDY
Inform Development.
726 VS: Error in message reception
CAUSE
Software error
REMEDY
Inform Development; possibly reboot.
727 VS: Error in send function in SC
CAUSE
Software error
REMEDY
Inform Development; possibly reboot.
728 VS: Unknown state
CAUSE
Software error
REMEDY
Inform Development; possibly reboot.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 79
729 VS: Upload data incorrect
CAUSE
Obsolete MVS software, MVS error.
REMEDY
Reboot; update eproms (MVS).
730 NF: software error
CAUSE
Incorrect message at NF (Info1)
REMEDY
If possible, ignore; possibly reboot.
731 NF: GLC NOK
CAUSE
Internal transmission error
REMEDY
Try again; if possible, ignore.
732 MA data: unknown spacer type
CAUSE
In aktuell.ma or *.vkl there is a spacer type which cannot be found in real.ma.
REMEDY
Establish consistency in the files aktuell.ma, *vkl and real.ma.
733 SF: unexpected input:
CAUSE
Incorrect message to single function (Info1), operator error during transition to single function or fatal
error handling ( start button not pressed )
REMEDY
If possible, ignore; possibly reboot.
734 SF: answer from wrong MC
CAUSE
System error
REMEDY
Reboot
735 SF: global communication not ok
CAUSE
Communication between machine controller and station computer disturbed.
REMEDY
Try communicating again.