19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 82 750 Data preparation : interna l error CAUSE ● Not poss ible to writ e to statio n computer har…

100%1 / 736
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 81
743 LRS: Interface or driver not found
CAUSE
Does not occur
REMEDY
744 LRS: Command not in command list
CAUSE
LR SEND incorrect command received
REMEDY
If possible, ignore.
745 LRS: Conversion is not possible
CAUSE
Could not convert data for line computer telegrams SABR/SBES.
REMEDY
No
746 LRS: No communication with line computer
CAUSE
IEC bus is "blocked"
REMEDY
Reboot station and line computers.
747 DP: Data limits exceeded
CAUSE
Incorrect date input
REMEDY
Correct input date
748 DP: required equipment unknown
CAUSE
Possibly the TASKS.CFG file has been changed, or there is a software fault
REMEDY
Reboot with the supplied version of TASKS.CFG ; if necessary, notify AUT 5 BSM 14
Development department
749 No PCB barcode read
CAUSE
Barcode reader has been activated but barcode was not recognized
REMEDY
Make sure the barcode type is correct; make sure the mechanical distance is correct
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 82
750 Data preparation : internal error
CAUSE
Not possible to write to station computer hard disk.
REMEDY
Check disk; disk full?; files write-protected ? (check *.MA, *.GF, *.NU, *.RU)
751 Data preparation : run error
CAUSE
If there was previously an error in the placement data (MK/GF/RU/NU files) all other telegrams com-
ing from the line computer will be discarded and in each case a message generated.
REMEDY
Reboot station (a great deal of specialist knowledge is required for precise identification of this fault).
752 Data preparation : error in machine data
CAUSE
It was not possible to convert the MA data (files AKTUELL.MA, REAL.MA, IDEAL.MA, RASTER.P1,
RASTER.P2).
REMEDY
Check the hard disk for bad clusters with the DOS program using the CHKDSK command; reinstall
machine data (files) onto the hard disk.
753 Data preparation : error in cluster data
CAUSE
It was not possible to convert the NU data.
REMEDY
The line computer has generated a faulty cluster, check data in line computer.
754 Data preparation : error in set-up data
CAUSE
It was not possible to convert the RU data.
REMEDY
The line computer has generated a faulty set-up, check data in line computer.
755 Data preparation : error in package form data
CAUSE
GF could not be converted.
REMEDY
Check GF in the line computer.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 83
756 Data preparation : error in fiducial data
CAUSE
MK could not be converted.
REMEDY
If this occurs only with a pure SIPLACE line (with MVS) it is best simply to reteach the MK.
757 Data preparation : error in fiducial list
CAUSE
Does not occur.
REMEDY
758 LR: Error reading telegram
CAUSE
Separators or value fields in the line computer telegram are incorrect or overrun.
REMEDY
Check hard disk of the station (MS-DOS CHKDSK); reboot.
759 LR: Error in telegram output
CAUSE
Does not occur
REMEDY
760 LR: Error during telegram treatment
CAUSE
Does not occur.
REMEDY
761 LR: No memory, task stopped
CAUSE
Memory of the station is not fragmented.
REMEDY
Reboot station.
762 VS: Maximal gradient number of fiducial profile exceeded
CAUSE
Fiducial structure with poor contrast value as background; horizontal / vertical fiducial profile which
contains more than 100 gradients which reach 20% of maximum gradients.
REMEDY
Reduce template field, select another fiducial structure.