19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 84 763 BO: Error dur. memory r equest f. text pool (no./length) CAUSE ● System error, not en ough …

100%1 / 736
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 83
756 Data preparation : error in fiducial data
CAUSE
MK could not be converted.
REMEDY
If this occurs only with a pure SIPLACE line (with MVS) it is best simply to reteach the MK.
757 Data preparation : error in fiducial list
CAUSE
Does not occur.
REMEDY
758 LR: Error reading telegram
CAUSE
Separators or value fields in the line computer telegram are incorrect or overrun.
REMEDY
Check hard disk of the station (MS-DOS CHKDSK); reboot.
759 LR: Error in telegram output
CAUSE
Does not occur
REMEDY
760 LR: Error during telegram treatment
CAUSE
Does not occur.
REMEDY
761 LR: No memory, task stopped
CAUSE
Memory of the station is not fragmented.
REMEDY
Reboot station.
762 VS: Maximal gradient number of fiducial profile exceeded
CAUSE
Fiducial structure with poor contrast value as background; horizontal / vertical fiducial profile which
contains more than 100 gradients which reach 20% of maximum gradients.
REMEDY
Reduce template field, select another fiducial structure.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 84
763 BO: Error dur. memory request f. text pool (no./length)
CAUSE
System error, not enough memory available.
REMEDY
764 BO: Cannot open text file
CAUSE
Text file not found.
REMEDY
The name of the text file is in the file C:\Texte\SITXT.CFG. If this file does not exist, the software
must be reinstalled.
765 BO: Text index too large (text index/max index)
CAUSE
A text in the text file is too large.
REMEDY
Ignore but inform AUT 5 BSM 14 Development.
766 BO: Text index defined twice (text index/i. )
CAUSE
On loading texts, double text indices were detected. Loading is repeated.
REMEDY
Ignore, but inform AUT 5 BSM 14 Development.
767 PCB barcode: incorrect format
CAUSE
The machine has not identified the board barcode received from the barcode reader.
REMEDY
Input manually via the keyboard or try again. Once placement of the current board is complete the
error menu will drop down.
768 No data received from PCB barcode reader
CAUSE
PCB barcode reader not responding.
REMEDY
Check PCB barcode reader.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 85
769 Barcode too long, cut off!
CAUSE
The maximum permissible length of the board barcode is 25 characters, of the component 20 char-
acters; a longer barcode was received, but was cut short.
REMEDY
The machine carries on working with the shortened barcode.
770 BL: unexpected input
CAUSE
System error
REMEDY
If possible, ignore.
771 VS: Communication between SR and MC defective
CAUSE
Software error
REMEDY
Reboot, if occurs repeatedly inform Development.
772 EH: received CODE unknown
CAUSE
Incorrect message to task EH.
REMEDY
If possible, ignore.
773 EH: received IDENT unknown
CAUSE
Incorrect message to task EH.
REMEDY
If possible, ignore.
774 EH: MC sending too many error messages (> F_FM_MAX)
CAUSE
Error handling can receive a maximum of 200 error messages at the same time from the machine
controller.
REMEDY
The error messages > 200 are discarded.