00191025-01 - 第672页

SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 85 769 Barcode too long, cut off! CAUSE ● The ma ximum pe rmissible l ength of the board barc ode i…

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 84
763 BO: Error dur. memory request f. text pool (no./length)
CAUSE
System error, not enough memory available.
REMEDY
764 BO: Cannot open text file
CAUSE
Text file not found.
REMEDY
The name of the text file is in the file C:\Texte\SITXT.CFG. If this file does not exist, the software
must be reinstalled.
765 BO: Text index too large (text index/max index)
CAUSE
A text in the text file is too large.
REMEDY
Ignore but inform AUT 5 BSM 14 Development.
766 BO: Text index defined twice (text index/i. )
CAUSE
On loading texts, double text indices were detected. Loading is repeated.
REMEDY
Ignore, but inform AUT 5 BSM 14 Development.
767 PCB barcode: incorrect format
CAUSE
The machine has not identified the board barcode received from the barcode reader.
REMEDY
Input manually via the keyboard or try again. Once placement of the current board is complete the
error menu will drop down.
768 No data received from PCB barcode reader
CAUSE
PCB barcode reader not responding.
REMEDY
Check PCB barcode reader.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 85
769 Barcode too long, cut off!
CAUSE
The maximum permissible length of the board barcode is 25 characters, of the component 20 char-
acters; a longer barcode was received, but was cut short.
REMEDY
The machine carries on working with the shortened barcode.
770 BL: unexpected input
CAUSE
System error
REMEDY
If possible, ignore.
771 VS: Communication between SR and MC defective
CAUSE
Software error
REMEDY
Reboot, if occurs repeatedly inform Development.
772 EH: received CODE unknown
CAUSE
Incorrect message to task EH.
REMEDY
If possible, ignore.
773 EH: received IDENT unknown
CAUSE
Incorrect message to task EH.
REMEDY
If possible, ignore.
774 EH: MC sending too many error messages (> F_FM_MAX)
CAUSE
Error handling can receive a maximum of 200 error messages at the same time from the machine
controller.
REMEDY
The error messages > 200 are discarded.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 86
775 Data preparation : cannot save current MA data
CAUSE
File "AKTUELL.MA" cannot be saved.
REMEDY
Check hard disk, check slide-in module, when rebooting update AKTUELL.MA, it may be that the
hard disk is full.
776 AKT: Error during system call ALOC
CAUSE
No memory allocated to Task T_AKT.
REMEDY
Reboot.
777 AKT: Incorrect input
CAUSE
Task AKT has received unknown message.
REMEDY
If possible, ignore, otherwise reboot.
778 AKT: Wrong data from data preparation
CAUSE
Data preparation sending incorrect "AKTUELL.MA" format to task T_AKT.
REMEDY
System error, reboot.
779 Undefined operation with and without LC
CAUSE
The station computer receives a message from the line computer, but it was input at station com-
puter as "without LC".
REMEDY
Input mode "with LC" at the station computer.
780 Undefined error in LC reception
CAUSE
Error when receiving via IEC bus.
REMEDY
Reboot.
781 No memory available
CAUSE
Memory in station computer is fragmented.
REMEDY
Reboot.