19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 86 775 Data preparation : cannot s ave current MA data CAUSE ● File "AKT UELL.MA" cann o…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 85
769 Barcode too long, cut off!
CAUSE
●
The maximum permissible length of the board barcode is 25 characters, of the component 20 char-
acters; a longer barcode was received, but was cut short.
REMEDY
●
The machine carries on working with the shortened barcode.
770 BL: unexpected input
CAUSE
●
System error
REMEDY
●
If possible, ignore.
771 VS: Communication between SR and MC defective
CAUSE
●
Software error
REMEDY
●
Reboot, if occurs repeatedly inform Development.
772 EH: received CODE unknown
CAUSE
●
Incorrect message to task EH.
REMEDY
●
If possible, ignore.
773 EH: received IDENT unknown
CAUSE
●
Incorrect message to task EH.
REMEDY
●
If possible, ignore.
774 EH: MC sending too many error messages (> F_FM_MAX)
CAUSE
●
Error handling can receive a maximum of 200 error messages at the same time from the machine
controller.
REMEDY
●
The error messages > 200 are discarded.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 86
775 Data preparation : cannot save current MA data
CAUSE
●
File "AKTUELL.MA" cannot be saved.
REMEDY
●
Check hard disk, check slide-in module, when rebooting update AKTUELL.MA, it may be that the
hard disk is full.
776 AKT: Error during system call ALOC
CAUSE
●
No memory allocated to Task T_AKT.
REMEDY
●
Reboot.
777 AKT: Incorrect input
CAUSE
●
Task AKT has received unknown message.
REMEDY
●
If possible, ignore, otherwise reboot.
778 AKT: Wrong data from data preparation
CAUSE
●
Data preparation sending incorrect "AKTUELL.MA" format to task T_AKT.
REMEDY
●
System error, reboot.
779 Undefined operation with and without LC
CAUSE
●
The station computer receives a message from the line computer, but it was input at station com-
puter as "without LC".
REMEDY
●
Input mode "with LC" at the station computer.
780 Undefined error in LC reception
CAUSE
●
Error when receiving via IEC bus.
REMEDY
●
Reboot.
781 No memory available
CAUSE
●
Memory in station computer is fragmented.
REMEDY
●
Reboot.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 87
782 Defective or incomplete telegram from LC
CAUSE
●
Unknown telegram from the line computer (may be incomplete)
REMEDY
●
Respecify placement program in the line computer.
783 Error during data transmission via IEC bus (LISTEN)
CAUSE
●
IEC bus disturbed
REMEDY
●
Reboot line and station computers.
784 Error during system call
CAUSE
●
System error
REMEDY
●
Reboot.
785 No version indicated in table program
CAUSE
●
Obsolete table program (TISCH.HEX)
REMEDY
●
Update TISCH.HEX.
786 BO: Cannot initialize text pointer (lmbx/)
CAUSE
●
System error when initializing text for task with the mailbox ID lmbx
REMEDY
●
Reset system
787 TA: Error while writing to disk
CAUSE
●
The file from the "Test output" task cannot be written to disk.
REMEDY
●
Check the hardware (hard disk): is the hard disk full ? Can the corresponding directory be found ?
788 TA: Error in aloc
CAUSE
●
No memory allocated.
REMEDY
●
System error; reset.