19 - 87
782 Defective or incomplete telegram from LC
CAUSE
Unknown telegram from the line computer (may be incomplete)
REMEDY
Respecify placement program in the line computer.
783 Error during data transmission via IEC bus (LISTEN)
CAUSE
IEC bus disturbed
REMEDY
Reboot line and station computers.
784 Error during system call
CAUSE
System error
REMEDY
Reboot.
785 No version indicated in table program
CAUSE
Obsolete table program (TISCH.HEX)
REMEDY
Update TISCH.HEX.
786 BO: Cannot initialize text pointer (lmbx/)
CAUSE
System error when initializing text for task with the mailbox ID lmbx
REMEDY
Reset system
787 TA: Error while writing to disk
CAUSE
The file from the "Test output" task cannot be written to disk.
REMEDY
Check the hardware (hard disk): is the hard disk full ? Can the corresponding directory be found ?
788 TA: Error in aloc
CAUSE
No memory allocated.
REMEDY
System error; reset.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 88
789 BO: No text file name in text configuration file
CAUSE
Error when reading the text file name from the file C:\TEXTE\SITXT_L.CFG
REMEDY
Check text file and name in C:\TEXTE\SITXT_L.CFG.
790 BO: Error while closing text configuration file
CAUSE
System error: opened file can no longer be closed.
REMEDY
Reset station.
791 BO: Error in ALOC 1. text pool (length 1000./1.)
CAUSE
Not enough memory available to read in the text file.
REMEDY
Reset station.
792 BO: Error while reading text file
CAUSE
Erroneous text file.
REMEDY
Check text file; check hard disk with CHKDSK.
793 BO: Error while closing text file
CAUSE
System error: opened file can no longer be closed.
REMEDY
Reset station.
794 BO: Incorrect text index (character/ith character)
CAUSE
Contents of the text file faulty.
REMEDY
If the error occurs again after error message 704, reset station. Text file faulty at the position ith char-
acter.
795 BO: Text line interrupted at index (character/i)
CAUSE
Contents of the text file faulty.
REMEDY
If the error occurs again after error message 704, reset station.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 89
796 BO: Text line interrupted at length (character/i)
CAUSE
Contents of the text file are faulty.
REMEDY
If the error occurs again after error message 704, reset station.
797 BO: Text line interrupted at type (character/i)
CAUSE
Contents of the text file are faulty.
REMEDY
If the error occurs again after error message 704, reset station.
798 BO: Text line interrupted at name (character/i)
CAUSE
Contents of the text file are faulty.
REMEDY
If the error occurs again after error message 704, reset station.
799 BO: Unknown state while loading texts (state)
CAUSE
System error while loading the texts.
REMEDY
Reset station.
800 BO: Text too long (text index/actual length)
CAUSE
A text is longer than permitted.
REMEDY
If the error occurs again after error message 704, inform Development.
801 BO: Invalid length information (text index/ith char)
CAUSE
Contents of the text file are faulty.
REMEDY
If the error occurs again after error message 704, reset station.
802 BO: Postponement line full (ident/code)
CAUSE
The operator interface is receiving too many jobs and cannot process these.
REMEDY
Reset station.