19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 98 859 MA dat a: Invalid comp artment at n ozzle changer CAUSE ● An inva lid compar tment numb er …

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 97
852 DP: Cannot save current MA data
CAUSE
●
Not possible to change or rewrite the aktuell.ma file
REMEDY
●
Hard disk should be checked
853 MA data: Invalid fiducial number for system fiducial
CAUSE
●
System fiducials must lie within the range 250 to 255
REMEDY
●
Correct the fiducial data in the MA data or set-up.
854 MA data: Error in sensor system types
CAUSE
●
Different sensor system types, or invalid for machine, in real.ma and ideal.ma
quoted (line computer telegram).
REMEDY
●
Make data consistent.
855 MA data: Missing height offset
CAUSE
●
Height offset not entered in real.ma.
REMEDY
●
Measure height offset and enter in real.ma.
856 MA data: Too many zero point fiducials
CAUSE
●
More than one zero point fiducial has been entered in ideal.ma.
REMEDY
●
Enter one fiducial only.
857 MA data: Mapping plate irregular
CAUSE
●
Irregular mapping plate is not supported.
REMEDY
●
Raster.px file should be checked; if necessary, remeasure
858 MA data: Error in nozzle type/vacuum correction values
CAUSE
●
For nozzle type in aktuell.ma no vacuum correction values can be found.
REMEDY
●
Enter valid nozzle type in aktuell.ma.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 98
859 MA data: Invalid compartment at nozzle changer
CAUSE
●
An invalid compartment number has been entered in aktuell.ma or real.ma
REMEDY
●
Make the data consistent again.
860 MA data: Unknown nozzle changer type
CAUSE
●
An invalid nozzle changer type has been specified in aktuell.ma or real.ma.
REMEDY
●
Make the data consistent again.
861 Cluster data: Error in nozzle type/vacuum correction values
CAUSE
●
Error must not occur; for the nozzle type specified in the cluster nozzle type there are no vacuum
correction values in ideal.ma.
REMEDY
●
Check consistency in the line computer.
862 Cluster data: Error in chain of placement positions
CAUSE
●
Error in the line computer telegram for cluster
REMEDY
●
Cluster should be checked in the line computer ; if necessary, compile again (feasibility)
863 Cluster data: Error in passpoint sets
CAUSE
●
Error in the line computer telegram for cluster.
REMEDY
●
Cluster should be checked in the line computer; if necessary, compile again (feasibility).
864 Cluster data: incorrect track number
CAUSE
●
Incorrect track number in cluster or set-up.
REMEDY
●
Cluster and set-up should be checked in the line computer; feasibility.
865 Cluster data: Error during creation of fiducial list
CAUSE
●
Software error
REMEDY
●
AUT 5 BSM 14 Development should be notified.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 99
866 Clust. data: Number fiducials or passpoint to large
CAUSE
●
Cluster in the line computer contains too many fiducials or passpoints.
REMEDY
●
Cluster should be checked in the line computer; feasibility.
867 Clust. data: Invalid X/Y offset 0 in individual circuit
CAUSE
●
Error in the line computer telegram; offset must not be 0.
REMEDY
●
Cluster should be checked in the line computer; feasibility.
868 Clust. data: Invalid location for machine type
CAUSE
●
Error in the cluster telegram
REMEDY
●
Cluster and set-up should be checked in the line computer; feasibility
869 Clust. data: Incorrect reference in placement options
CAUSE
●
Incorrect reference in the placement positions.
REMEDY
●
Check line computer data.
870 Set-up data: Error during conversion of tracks
CAUSE
●
Error during conversion of tracks.
REMEDY
●
Check line computer data.
871 Set-up data: Missing track chain
CAUSE
●
Software error
REMEDY
●
AUT 5 BSM 14 Development should be notified.
872 Set-up data: Invalid location for machine type
CAUSE
●
Faulty set-up telegram from the line computer
REMEDY
●
Set-up should be checked; feasibility.