00191025-01 - 第686页
SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 99 866 Clust. data: Number fiducial s or passpoint to large CAUSE ● Cluster i n the line co mputer …

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 98
859 MA data: Invalid compartment at nozzle changer
CAUSE
●
An invalid compartment number has been entered in aktuell.ma or real.ma
REMEDY
●
Make the data consistent again.
860 MA data: Unknown nozzle changer type
CAUSE
●
An invalid nozzle changer type has been specified in aktuell.ma or real.ma.
REMEDY
●
Make the data consistent again.
861 Cluster data: Error in nozzle type/vacuum correction values
CAUSE
●
Error must not occur; for the nozzle type specified in the cluster nozzle type there are no vacuum
correction values in ideal.ma.
REMEDY
●
Check consistency in the line computer.
862 Cluster data: Error in chain of placement positions
CAUSE
●
Error in the line computer telegram for cluster
REMEDY
●
Cluster should be checked in the line computer ; if necessary, compile again (feasibility)
863 Cluster data: Error in passpoint sets
CAUSE
●
Error in the line computer telegram for cluster.
REMEDY
●
Cluster should be checked in the line computer; if necessary, compile again (feasibility).
864 Cluster data: incorrect track number
CAUSE
●
Incorrect track number in cluster or set-up.
REMEDY
●
Cluster and set-up should be checked in the line computer; feasibility.
865 Cluster data: Error during creation of fiducial list
CAUSE
●
Software error
REMEDY
●
AUT 5 BSM 14 Development should be notified.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 99
866 Clust. data: Number fiducials or passpoint to large
CAUSE
●
Cluster in the line computer contains too many fiducials or passpoints.
REMEDY
●
Cluster should be checked in the line computer; feasibility.
867 Clust. data: Invalid X/Y offset 0 in individual circuit
CAUSE
●
Error in the line computer telegram; offset must not be 0.
REMEDY
●
Cluster should be checked in the line computer; feasibility.
868 Clust. data: Invalid location for machine type
CAUSE
●
Error in the cluster telegram
REMEDY
●
Cluster and set-up should be checked in the line computer; feasibility
869 Clust. data: Incorrect reference in placement options
CAUSE
●
Incorrect reference in the placement positions.
REMEDY
●
Check line computer data.
870 Set-up data: Error during conversion of tracks
CAUSE
●
Error during conversion of tracks.
REMEDY
●
Check line computer data.
871 Set-up data: Missing track chain
CAUSE
●
Software error
REMEDY
●
AUT 5 BSM 14 Development should be notified.
872 Set-up data: Invalid location for machine type
CAUSE
●
Faulty set-up telegram from the line computer
REMEDY
●
Set-up should be checked; feasibility.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 100
873 Set-up data: Unknown sensor system type
CAUSE
●
Software error
REMEDY
●
AUT 5 BSM 14 Development should be notified.
874 Set-up data: Invalid reference in set-up telegram
CAUSE
●
Faulty set-up telegram from the line computer.
REMEDY
●
Check line computer data.
875 Set-up data: Unknown nozzle changer type
CAUSE
●
Error in set-up telegram from line computer.
REMEDY
●
Check nozzle changer type in the line computer.
876 Set-up data: Unknown track type in set-up telegram
CAUSE
●
Faulty set-up telegram from the line computer.
REMEDY
●
Check line computer data.
877 Set-up data: Error while writing WPC set-up
CAUSE
●
It was not possible to access the hard disk.
REMEDY
●
Check hard disk (consistency, storage capacity)
878 PF data: first PF number = 0; PF telegram faulty
CAUSE
●
Transfer a zero into the PF telegram as PF number.
REMEDY
●
Check line computer data.
879 PF data: Unknown sensor system type
CAUSE
●
This type of sensor system does not exist for this machine type
REMEDY
●
Check line computer data.