SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 1 01 880 PF data: Error in internal PF list CAUSE ● Softwar e error REMEDY ● AUT 5 B SM 14 Devel op…

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 100
873 Set-up data: Unknown sensor system type
CAUSE
Software error
REMEDY
AUT 5 BSM 14 Development should be notified.
874 Set-up data: Invalid reference in set-up telegram
CAUSE
Faulty set-up telegram from the line computer.
REMEDY
Check line computer data.
875 Set-up data: Unknown nozzle changer type
CAUSE
Error in set-up telegram from line computer.
REMEDY
Check nozzle changer type in the line computer.
876 Set-up data: Unknown track type in set-up telegram
CAUSE
Faulty set-up telegram from the line computer.
REMEDY
Check line computer data.
877 Set-up data: Error while writing WPC set-up
CAUSE
It was not possible to access the hard disk.
REMEDY
Check hard disk (consistency, storage capacity)
878 PF data: first PF number = 0; PF telegram faulty
CAUSE
Transfer a zero into the PF telegram as PF number.
REMEDY
Check line computer data.
879 PF data: Unknown sensor system type
CAUSE
This type of sensor system does not exist for this machine type
REMEDY
Check line computer data.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 101
880 PF data: Error in internal PF list
CAUSE
Software error
REMEDY
AUT 5 BSM 14 Development should be notified.
881 PF data: Number of PFs in telegram too large
CAUSE
Max. number of the package form descriptions in the PF telegram from the line computers has been
exceeded.
REMEDY
Cannot occur.
882 PF data: Model No. from group not in description
CAUSE
A model number has been specified in the group description which does not exist with this PF.
REMEDY
Check line computer data.
883 PF data: No reference to this PF in set-up
CAUSE
PF which is not required has been received from the line computer.
REMEDY
Check line computer data.
884 PF data: Sensor system type No. not in PF telegram
CAUSE
A sensor system type no. is specified in the PF telegram which is invalid for this machine type.
REMEDY
Check line computer data.
885 PF data: PF telegram not received from LC
CAUSE
PF required was not received from the line computer.
REMEDY
Check line computer data, feasibility
886 PF data: Deletion telegram for PF not available
CAUSE
Telegram from the line computer: deletion of PF which is not available.
REMEDY
Check line computer data.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 102
887 MK-data: Incorrect length of binary share
CAUSE
Fiducial telegram from the line computer or fiducial file faulty.
REMEDY
Check line computer data.
888 DP: First part of telegram missing
CAUSE
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
Check station computer / line computer software versions.
IEC - Check cables. Check file.
889 DP: Last part of telegram missing
CAUSE
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
Check station computer / line computer software versions.
IEC - Check cables. Check file.
890 DP: Telegram incomplete
CAUSE
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
Check station computer / line computer software versions.
IEC - Check cables. Check file.
891 DP: Invalid character in telegram
CAUSE
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
Check station computer / line computer software versions.
IEC - Check cables. Check file.