00191025-01 - 第691页
19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 104 897 DP: Glue identification lines not available CAUSE ● In aktuel l.ma the i ncorrect gl ue na…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 103
892 DP: Invalid telegram or file structure
CAUSE
●
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
●
Check station computer / line computer software versions.
IEC - Check cables. Check file.
893 DP: Invalid number format in telegram
CAUSE
●
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
●
Check station computer / line computer software versions.
IEC - Check cables. Check file.
894 DP: Error in telegram description
CAUSE
●
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
●
Check station computer / line computer software versions.
IEC - Check cables. Check file.
895 DP: Range limits in telegram exceeded
CAUSE
●
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
●
Check station computer / line computer software versions.
IEC - Check cables. Check file.
896 DP: String too long
CAUSE
●
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
●
Check station computer / line computer software versions.
IEC - Check cables. Check file.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 104
897 DP: Glue identification lines not available
CAUSE
●
In aktuell.ma the incorrect glue name was specified
REMEDY
●
Correct the data in aktuell.ma
898 DP: VKL data not available
CAUSE
●
A glue name specified in aktuell.ma is not available *.VKL file
REMEDY
●
Correct aktuell.ma and *.VKL file
899 DP: INI data not available
CAUSE
●
A glue name specified in aktuell.ma is not available as *.INI file
REMEDY
●
Correct aktuell.ma and *.INI file
900 OPT: Error during data reception
CAUSE
●
Software error between data preparation and glue optimization
REMEDY
●
Cluster data should be corrected; reboot
901 OPT: Error during memory request
CAUSE
●
Software error in glue optimization: no more memory available
REMEDY
●
Files may be too large; reboot
902 OPT: No memory received
CAUSE
●
Software error in glue optimization: no more memory available
REMEDY
●
Files may be too large; reboot
903 OPT: Error during look
CAUSE
●
Software error in glue optimization
REMEDY
●
Reboot

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 105
904 OPT: No glueing position received
CAUSE
●
Glue optimization received the glueing number "zero"
REMEDY
●
Check data
905 Glueing size not possible with glue available
CAUSE
●
Glueing size specified by the line computer in this cluster is not possible with the glue set up
REMEDY
●
Set up glue again
906 OPT: Glueing size received is invalid
CAUSE
●
Glueing size is larger than 20
REMEDY
●
Check data
907 OPT: Glueing position outside of travel range
CAUSE
●
Optimization received a position outside the travel range
REMEDY
●
Travel range and cluster should be checked
908 Caution: PCB transported through by line computer
CAUSE
●
Board barcode has been sent to line computer; the line computer does not have this barcode in its
list
REMEDY
●
Wrong board fed in; something wrong with the list in the line computer.
909 DP: Glue type list KLL incorrectly loaded
CAUSE
●
Faulty data (*.vkl, SIPLACE.KLL) on the hard disk
REMEDY
●
Check all *.vkl files (including file name in the file)
910 VS: Search for array index not successful
CAUSE
●
The job file is not consistent
REMEDY
●
Check the camera records in REAL.MA; check the job data (GF data) in the line computer.