19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 106 911 OPT: Space r in contact with glueing point CAUSE ● Gluein g points are too close together …

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 105
904 OPT: No glueing position received
CAUSE
●
Glue optimization received the glueing number "zero"
REMEDY
●
Check data
905 Glueing size not possible with glue available
CAUSE
●
Glueing size specified by the line computer in this cluster is not possible with the glue set up
REMEDY
●
Set up glue again
906 OPT: Glueing size received is invalid
CAUSE
●
Glueing size is larger than 20
REMEDY
●
Check data
907 OPT: Glueing position outside of travel range
CAUSE
●
Optimization received a position outside the travel range
REMEDY
●
Travel range and cluster should be checked
908 Caution: PCB transported through by line computer
CAUSE
●
Board barcode has been sent to line computer; the line computer does not have this barcode in its
list
REMEDY
●
Wrong board fed in; something wrong with the list in the line computer.
909 DP: Glue type list KLL incorrectly loaded
CAUSE
●
Faulty data (*.vkl, SIPLACE.KLL) on the hard disk
REMEDY
●
Check all *.vkl files (including file name in the file)
910 VS: Search for array index not successful
CAUSE
●
The job file is not consistent
REMEDY
●
Check the camera records in REAL.MA; check the job data (GF data) in the line computer.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 106
911 OPT: Spacer in contact with glueing point
CAUSE
●
Glueing points are too close together or their position relative to the spacer is not good.
REMEDY
●
Reposition the spacer and reoptimize the cluster.
NOTE
The spacer angle must be input in the "Modify system data" menu.
912 DP: axis type incorrect in small gantry mapping data
CAUSE
●
Incorrect axis type in the RASTER.K1 file (mapping data for glueing station for small gantries)
REMEDY
●
Make the necessary correction in the machine file RASTER.K1 (axis type).
913 DP: errors in gantry ident. in small gantry map. data
CAUSE
●
Incorrect gantry identification in RASTER.K1 file (mapping data for glueing station for small gantries)
REMEDY
●
Make the necessary correction in the machine file RASTER.K1 (axis type).
1001 Undefined error message
CAUSE
●
Error does not occur
REMEDY
●
1002 Undefined error message
CAUSE
●
Error does not occur
REMEDY
●
1003 Undefined error message
CAUSE
●
Error does not occur
REMEDY
●

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 107
1004 Undefined error message
CAUSE
●
Error does not occur
REMEDY
●
1005 z axis; GU1: Bero at top does not react
CAUSE
●
z1 axis is not positioned high enough; Bero defective; z1 axis is jamming
motor, controller, servo-amplifier defective.
REMEDY
●
Check the components just mentioned.
1006 Glue: z axis; GU2: Bero at top does not react
CAUSE
●
z2 axis is not positioned high enough; Bero defective; z2 axis is jamming
motor, controller, servo-amplifier defective.
REMEDY
●
Check the components just mentioned.
1007 Glue: z axis; GU3: Bero at top does not react
CAUSE
●
z3 axis is not positioned high enough; Bero defective; z3 axis is jamming
motor, controller, servo-amplifier defective.
REMEDY
●
Check the components just mentioned.
1008 Undefined error message
CAUSE
●
Error does not occur
REMEDY
●
1009 Undefined error message
CAUSE
●
Error does not occur