00191025-01 - 第697页
19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 110 1022 z axis ; GU3: T arget pos ition no t reache d CAUSE ● Machine data not c orrect; mech ani…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 109
1017 z axis; GU3: Position outside of travel range
CAUSE
●
Not used
REMEDY
●
1018 xk axis: Target position not reached
CAUSE
●
Machine data not correct; mechanism is jamming;
drive motor, tachometer, incremental encoder, servo-amplifier defective; calibration of the axis incor-
rect.
REMEDY
●
Check machine data; check the mechanism; check the axis calibration
or check the components; if necessary, replace
1019 yk axis: Target position not reached
CAUSE
●
Machine data not correct; mechanism is jamming;
drive motor, tachometer, incremental encoder, servo-amplifier defective; calibration of the axis incor-
rect.
REMEDY
●
Check machine data; check the mechanism; check the axis calibration
or check the components; if necessary, replace
1020 z axis; GU1: Target position not reached
CAUSE
●
Machine data not correct; mechanism is jamming;
drive motor, tachometer, incremental encoder, servo-amplifier defective; calibration of the axis incor-
rect. Cam is in incorrect position with respect to zero pulse
REMEDY
●
Check machine data; check the mechanism; check the axis calibration
or check the components; if necessary, replace, fit cam in correct rotational position; redetermine
zero point correction
1021 z axis; GU2: Target position not reached
CAUSE
●
Machine data not correct; mechanism is jamming;
drive motor, tachometer, incremental encoder, servo-amplifier defective; calibration of the axis incor-
rect.
Cam is in incorrect position with respect to zero pulse
REMEDY
●
Check machine data; check the mechanism; check the axis calibration
or check the components; if necessary, replace, fit cam in correct rotational position; redetermine
zero point correction

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 110
1022 z axis; GU3: Target position not reached
CAUSE
●
Machine data not correct; mechanism is jamming;
drive motor, tachometer, incremental encoder, servo-amplifier defective; calibration of the axis incor-
rect.
Cam is in incorrect position with respect to zero pulse
REMEDY
●
Check machine data; check the mechanism; check the axis calibration
or check the components; if necessary, replace, fit cam in correct rotational position; redetermine
zero point correction
1023 xk axis: deactivated
CAUSE
●
Axis has been deactivated at the axis board (servo)
REMEDY
●
Switch on the axis at the axis card
1024 yk axis: deactivated
CAUSE
●
Axis has been deactivated at the axis board (servo)
REMEDY
●
Switch on the axis at the axis card
1025 z axis; GU1: deactivated
CAUSE
●
Axis has been deactivated at the axis board (servo)
REMEDY
●
Switch on the axis at the axis card
1026 z axis; GU2: deactivated
CAUSE
●
Axis has been deactivated at the axis board (servo)
REMEDY
●
Switch on the axis at the axis card
1027 z axis; GU3: deactivated
CAUSE
●
Axis has been deactivated at the axis board (servo)
REMEDY
●
Switch on the axis at the axis card

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 111
1028 xk axis: Position control does not work
CAUSE
●
The position control of the axis is not working properly; machine data are not correct
REMEDY
●
Switch off the machine (reset), check axis for stiffness of running; check the machine data
1029 yk axis: Position control does not work
CAUSE
●
The position control of the axis is not working properly; machine data are not correct
REMEDY
●
Switch off the machine (reset), check axis for stiffness of running; check the machine data
1030 z axis; GU1: Position control does not work
CAUSE
●
The position control of the axis is not working properly; machine data are not correct
REMEDY
●
Switch off the machine (reset), check axis for stiffness of running; check the machine data
1031 z axis; GU2: Position control does not work
CAUSE
●
The position control of the axis is not working properly; machine data are not correct
REMEDY
●
Switch off the machine (reset), check axis for stiffness of running; check the machine data
1032 z axis; GU3: Position control does not work
CAUSE
●
The position control of the axis is not working properly; machine data are not correct
REMEDY
●
Switch off the machine (reset), check axis for stiffness of running; check the machine data
1033 X axis: deactivated
CAUSE
●
Axis has been deactivated at the axis board (servo)
REMEDY
●
Switch on the axis at the axis card
1034 Y axis: deactivated
CAUSE
●
Axis has been deactivated at the axis board (servo)
REMEDY
●
Switch on the axis at the axis card