00191025-01 - 第698页

SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 1 11 1028 xk ax is: Position control does not work CAUSE ● The po sition cont rol of the axis is n …

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 110
1022 z axis; GU3: Target position not reached
CAUSE
Machine data not correct; mechanism is jamming;
drive motor, tachometer, incremental encoder, servo-amplifier defective; calibration of the axis incor-
rect.
Cam is in incorrect position with respect to zero pulse
REMEDY
Check machine data; check the mechanism; check the axis calibration
or check the components; if necessary, replace, fit cam in correct rotational position; redetermine
zero point correction
1023 xk axis: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1024 yk axis: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1025 z axis; GU1: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1026 z axis; GU2: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1027 z axis; GU3: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 111
1028 xk axis: Position control does not work
CAUSE
The position control of the axis is not working properly; machine data are not correct
REMEDY
Switch off the machine (reset), check axis for stiffness of running; check the machine data
1029 yk axis: Position control does not work
CAUSE
The position control of the axis is not working properly; machine data are not correct
REMEDY
Switch off the machine (reset), check axis for stiffness of running; check the machine data
1030 z axis; GU1: Position control does not work
CAUSE
The position control of the axis is not working properly; machine data are not correct
REMEDY
Switch off the machine (reset), check axis for stiffness of running; check the machine data
1031 z axis; GU2: Position control does not work
CAUSE
The position control of the axis is not working properly; machine data are not correct
REMEDY
Switch off the machine (reset), check axis for stiffness of running; check the machine data
1032 z axis; GU3: Position control does not work
CAUSE
The position control of the axis is not working properly; machine data are not correct
REMEDY
Switch off the machine (reset), check axis for stiffness of running; check the machine data
1033 X axis: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1034 Y axis: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 112
1035 xk axis: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1036 yk axis: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1037 z axis; GU1: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1038 z axis; GU2: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1039 z axis; GU3: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1040 X axis: Timeout
CAUSE
Axis does not reach position within the specified time; axis setting is not correct; machine data not
correct; drive motor, tachometer, incremental encoder, servo-amplifier defective;
mechanism is jamming
REMEDY
Check the axis calibration; check machine data; or check the components; if necessary, replace;
check the mechanism;