00191025-01 - 第701页
19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 114 1046 z axis ; GU3: T imeout CAUSE ● Axis does not rea ch posit ion within the spec ified tim e…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 113
1041 Y axis: Timeout
CAUSE
●
Axis does not reach position within the specified time; axis setting is not correct; machine data not
correct; drive motor, tachometer, incremental encoder, servo-amplifier defective;
mechanism is jamming
REMEDY
●
Check the axis calibration; check machine data; or check the components; if necessary, replace;
check the mechanism;
1042 xk axis: Timeout
CAUSE
●
Axis does not reach position within the specified time; axis setting is not correct; machine data not
correct; drive motor, tachometer, incremental encoder, servo-amplifier defective;
mechanism is jamming
REMEDY
●
Check the axis calibration; check machine data; or check the components; if necessary, replace;
check the mechanism;
1043 yk axis: Timeout
CAUSE
●
Axis does not reach position within the specified time; axis setting is not correct; machine data not
correct; drive motor, tachometer, incremental encoder, servo-amplifier defective;
mechanism is jamming
REMEDY
●
Check the axis calibration; check machine data; or check the components; if necessary, replace;
check the mechanism;
1044 z axis; GU1: Timeout
CAUSE
●
Axis does not reach position within the specified time; axis setting is not correct; machine data not
correct; drive motor, tachometer, incremental encoder, servo-amplifier defective;
mechanism is jamming.
REMEDY
●
Check the axis calibration; check machine data; or check the components; if necessary, replace;
check the mechanism;
1045 z axis; GU2: Timeout
CAUSE
●
Axis does not reach position within the specified time; axis setting is not correct; machine data not
correct; drive motor, tachometer, incremental encoder, servo-amplifier defective;
mechanism is jamming.
REMEDY
●
Check the axis calibration; check machine data; or check the components; if necessary, replace;
check the mechanism;

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 114
1046 z axis; GU3: Timeout
CAUSE
●
Axis does not reach position within the specified time; axis setting is not correct; machine data not
correct; drive motor, tachometer, incremental encoder, servo-amplifier defective;
mechanism is jamming.
REMEDY
●
Check the axis calibration; check machine data; or check the components; if necessary, replace;
check the mechanism;
1047 X axis: target position outside of travel range
CAUSE
●
The measurement of the head references does not match the travel range of the x axis.
REMEDY
●
Remeasure the head references; remeasure the minimum/maximum positions of the axis.
1048 Y axis: target position outside of travel range
CAUSE
●
The measurement of the head references does not match the travel range of the y axis.
REMEDY
●
Remeasure the head references; remeasure the minimum/maximum positions of the axis.
1049 xk axis: target position outside of travel range
CAUSE
●
The measurement of the head references does not match the travel range of the xk axis
REMEDY
●
Remeasure the head references; remeasure the minimum/maximum positions of the axis
1050 yk axis: target position outside of travel range
CAUSE
●
The measurement of the head references does not match the travel range of the yk axis
REMEDY
●
Remeasure the head references; remeasure the minimum/maximum positions of the yk axis
1051 z axis; GU1: target position outside of travel range
CAUSE
●
The minimum/maximum positions of the z1 axis are not correct; height of the head is not correct
REMEDY
●
Adjust the minimum/maximum positions and zero point correction correctly; specify the head height
correctly.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 115
1052 z axis; GU2: target position outside of travel range
CAUSE
●
The minimum/maximum positions of the z2 axis are not correct; height of the head is not correct
REMEDY
●
Adjust the minimum/maximum positions and zero point correction correctly; specify the head height
correctly.
1053 z axis; GU3: target position outside of travel range
CAUSE
●
The minimum/maximum positions of the z3 axis are not correct; height of the head is not correct
REMEDY
●
Adjust the minimum/maximum positions and zero point correction correctly; specify the head height
correctly.
1054 z axis; GU1: BERO for position monitoring off
CAUSE
●
When the gantry moves the z1 axis is not at the top; alignment of the Bero is faulty; Bero is defective
axis is jamming; motor, controller, servo defective
REMEDY
●
Inspect and if necessary repair or replace the components just mentioned
1055 z axis; GU2: BERO for position monitoring off
CAUSE
●
When the gantry moves the z2 axis is not at the top; alignment of the Bero is faulty; Bero is defective
axis is jamming; motor, controller, servo defective
REMEDY
●
Inspect and if necessary repair or replace the components just mentioned
1056 z axis; GU3: BERO for position monitoring off
CAUSE
●
When the gantry moves the z3 axis is not at the top; alignment of the Bero is faulty; Bero is defective
axis is jamming; motor, controller, servo defective
REMEDY
●
Inspect and if necessary repair or replace the components just mentioned
1057 X axis error: invalid command
CAUSE
●
Software error; should not occur
REMEDY
●