00191025-01 - 第713页

19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 126 1127 X-axis e rror: incorrect a cceleration CAUSE ● Invalid value in th e machine data REMEDY …

100%1 / 736
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 125
1120 X-axis error: Reference error
CAUSE
Invalid reference point type in the machine data
REMEDY
Check machine data
1121 Y-axis error: Reference error
CAUSE
Invalid reference point type in the machine data
REMEDY
Check machine data
1122 xk-axis error: Reference error
CAUSE
Invalid reference point type in the machine data
REMEDY
Check machine data
1123 yk-axis error: Reference error
CAUSE
Invalid reference point type in the machine data
REMEDY
Check machine data
1124 Z-axis error, GU1: Reference error
CAUSE
Invalid reference point type in the machine data
REMEDY
Check machine data
1125 Z-axis error; GU2: Reference error
CAUSE
Invalid reference point type in the machine data
REMEDY
Check machine data
1126 Z-axis error, GU3: Reference error
CAUSE
Invalid reference point type in the machine data
REMEDY
Check machine data
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 126
1127 X-axis error: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1128 Y-axis error: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1129 xk-axis error: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1130 yk-axis error: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1131 Z-axis error, GU1: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1132 Z-axis error; GU2: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1133 Z-axis error; GU3: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 127
1134 X-axis error: Reference point not found
CAUSE
Reference point not found on scale; scale dirty or defective
REMEDY
Check scale; repeat reference run
1135 Y-axis error: Reference point not found
CAUSE
Reference point not found on scale; scale dirty or defective
REMEDY
Check scale; repeat reference run
1136 xk-axis error: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1137 yk-axis error: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1138 Z-axis error, GU1: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1139 Z-axis error; GU2: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1140 Z-axis error; GU3: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit