00191025-01 - 第715页
19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 128 1141 X-axis e rror: I-square CAUSE ● R.m.s. current of the servo-am plifier ex ceeded; moto r …

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 127
1134 X-axis error: Reference point not found
CAUSE
●
Reference point not found on scale; scale dirty or defective
REMEDY
●
Check scale; repeat reference run
1135 Y-axis error: Reference point not found
CAUSE
●
Reference point not found on scale; scale dirty or defective
REMEDY
●
Check scale; repeat reference run
1136 xk-axis error: Reference point not found
CAUSE
●
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
●
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1137 yk-axis error: Reference point not found
CAUSE
●
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
●
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1138 Z-axis error, GU1: Reference point not found
CAUSE
●
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
●
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1139 Z-axis error; GU2: Reference point not found
CAUSE
●
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
●
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1140 Z-axis error; GU3: Reference point not found
CAUSE
●
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
●
Repeat reference run; check incremental pulses; if necessary, replace motor unit

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 128
1141 X-axis error: I-square
CAUSE
●
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
●
Motor current should be checked; carry out maintenance on mechanism
1142 Y-axis error: I-square
CAUSE
●
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
●
Motor current should be checked; carry out maintenance on mechanism
1143 xk-axis error: I-square
CAUSE
●
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
●
Motor current should be checked; carry out maintenance on mechanism
1144 yk-axis error: I-square
CAUSE
●
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
●
Motor current should be checked; carry out maintenance on mechanism
1145 Z-axis error, GU1: I-square
CAUSE
●
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
●
Motor current should be checked; carry out maintenance on mechanism
1146 Z-axis error; GU2: I-square
CAUSE
●
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
●
Motor current should be checked; carry out maintenance on mechanism
1147 Z-axis error; GU3: I-square
CAUSE
●
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
●
Motor current should be checked; carry out maintenance on mechanism

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 129
1148 GU does not execute command
CAUSE
●
When transmitting to the glueing unit it does not send an acknowledgement; V24 connection inter-
rupted; control board GU defective
REMEDY
●
V24 connection should be checked; control board GU should be repaired
1149 GU does not send data
CAUSE
●
When data is requested from the GU, it does not send any data
REMEDY
●
Hardware of MC-GU should be checked; V24 connection should be checked; carry out maintenance
on control board GU
1150 GU: Receiving buffer too small
CAUSE
●
Record length when sending or receiving to or from the GU exceeds the sending / receiving buffer
Software error - incompatible versions of MC and GU
REMEDY
●
Check versions
1151 GU: Checksum error
CAUSE
●
When sending to the GU a negative acknowledgement is received from the GU
REMEDY
●
Software error. AUT 5 BSM 14 Development should be notified
1152 GU: Checksum error in message from head
CAUSE
●
When receiving a message from the GU the checksum is not correct.
REMEDY
●
Software error of the GU. AUT 5 BSM 14 Development should be notified
1153 GU does not know command
CAUSE
●
The MC sends a command to the GU which is not defined
REMEDY
●
Incompatible versions of MC and GU