00191025-01 - 第718页
SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 1 31 1160 G U: incorrec t number of re cords CAUSE ● When re ceiving proc ess data from the GU the …

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 130
1154 GU is indicating error during glueing
CAUSE
●
Head not initialized: no pressure build-up; no venting; no pressure.
REMEDY
●
Check hoses, valves; inspect for leaks
1155 GU does not know pressure range
CAUSE
●
The pressure specified in the data command is inconsistent with the head file ( .ini),
*.vkl and *.ini file are not consistent. Software error
REMEDY
●
Check vkl and ini files
1156 RAM error in GU
CAUSE
●
During initialization of the GU the internal RAM memory is checked. If there is a fault this will be
reported at the first glueing action
REMEDY
●
Hardware GU should be checked/replaced
1157 GU: incorrect glueing command
CAUSE
●
The MC has sent a command to the GU which is not defined
REMEDY
●
MC/GU commands should be checked
1158 GU: incorrect record number during Send
CAUSE
●
When *.ini or process data were sent from MC to GU the record number was not correct
Software error or corrupt .ini or process data files.
REMEDY
●
.ini and process data files should be checked.
1159 GU: incorrect record number during Receive
CAUSE
●
When receiving process data from the GU the record sum was not correct. Software error in the GU
REMEDY
●
AUT 5 BSM 14 Development should be notified

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 131
1160 GU: incorrect number of records
CAUSE
●
When receiving process data from the GU the record sum was not correct. Software error in the GU
REMEDY
●
AUT 5 BSM 14 Development should be notified
1161 GU: Error during Reserve
CAUSE
●
While reserving the interface for the GU an error occurred. Software error
REMEDY
●
AUT 5 BSM 14 Development should be notified
1162 GU: Error during Release
CAUSE
●
While releasing the interface for the GU an error occurred. Software error
REMEDY
●
AUT 5 BSM 14 Development should be notified
1163 GU: Glueing order to head
CAUSE
●
While the glueing order was being sent to the GU an error occurred
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting
1164 GU: wait until glueing is finished
CAUSE
●
While waiting for the end message from the glueing unit an error occurred
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting
1165 GU: Error while setting desired temperature
CAUSE
●
While the desired temperature was being sent to the GU an error occurred
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting
1166 GU: Error while setting glueing point volume
CAUSE
●
While the glueing point volume change was being sent to the GU an error occurred
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 132
1167 GU: Error while setting new cartridge
CAUSE
●
An error occurred while a command was being sent to the GU that a new cartridge had been
inserted.
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting
1168 GU: Error while reading actual temperature
CAUSE
●
While the actual temperature was being requested for the GU an error occurred
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting
1169 GU: Error during Switch on continuous glueing
CAUSE
●
While the continuous glueing of the GU was being switched on an error occurred
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting
1170 GU: Error during Switch off continuous glueing
CAUSE
●
While the continuous glueing of the GU was being switched off an error occurred
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting
1171 Error during Send
INI data
to GU
CAUSE
●
An error occurred while .ini data was being sent to the GU
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting
1172 GU: Error during Send process data
CAUSE
●
An error occurred while process data was being sent to the GU.
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting
1173 GU: Error during Receive process data
CAUSE
●
An error occurred while process data was being received by the GU.
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting