00191025-01 - 第719页
19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 132 1167 GU: Error while setting new cartridge CAUSE ● An error occurred wh ile a com mand was bei…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 131
1160 GU: incorrect number of records
CAUSE
●
When receiving process data from the GU the record sum was not correct. Software error in the GU
REMEDY
●
AUT 5 BSM 14 Development should be notified
1161 GU: Error during Reserve
CAUSE
●
While reserving the interface for the GU an error occurred. Software error
REMEDY
●
AUT 5 BSM 14 Development should be notified
1162 GU: Error during Release
CAUSE
●
While releasing the interface for the GU an error occurred. Software error
REMEDY
●
AUT 5 BSM 14 Development should be notified
1163 GU: Glueing order to head
CAUSE
●
While the glueing order was being sent to the GU an error occurred
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting
1164 GU: wait until glueing is finished
CAUSE
●
While waiting for the end message from the glueing unit an error occurred
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting
1165 GU: Error while setting desired temperature
CAUSE
●
While the desired temperature was being sent to the GU an error occurred
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting
1166 GU: Error while setting glueing point volume
CAUSE
●
While the glueing point volume change was being sent to the GU an error occurred
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 132
1167 GU: Error while setting new cartridge
CAUSE
●
An error occurred while a command was being sent to the GU that a new cartridge had been
inserted.
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting
1168 GU: Error while reading actual temperature
CAUSE
●
While the actual temperature was being requested for the GU an error occurred
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting
1169 GU: Error during Switch on continuous glueing
CAUSE
●
While the continuous glueing of the GU was being switched on an error occurred
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting
1170 GU: Error during Switch off continuous glueing
CAUSE
●
While the continuous glueing of the GU was being switched off an error occurred
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting
1171 Error during Send
INI data
to GU
CAUSE
●
An error occurred while .ini data was being sent to the GU
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting
1172 GU: Error during Send process data
CAUSE
●
An error occurred while process data was being sent to the GU.
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting
1173 GU: Error during Receive process data
CAUSE
●
An error occurred while process data was being received by the GU.
REMEDY
●
Error is specified more precisely in a further message. Take this into account during troubleshooting

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 133
1174 WARNING: Fill cartridge before next PCB
CAUSE
●
Bero for "Empty cartridge" triggered; not enough glue left to glue the next board
REMEDY
●
Change cartridge and confirm
1175 Cartridge empty; PCB will not be processed
CAUSE
●
This was preceded by error 1174 and the cartridge was still not changed
REMEDY
●
Change cartridge and confirm
1176 Cleaning process must be started
CAUSE
●
One of the cleaning conditions has occurred. Not an error
REMEDY
●
The machine cleans itself automatically
1177 GU: Software error in RIO call
CAUSE
●
Software error
REMEDY
●
AUT 5 BSM 14 Development should be notified
1178 Actual temperature does not reach desired temperature
CAUSE
●
Glueing parameter controller did not reach the desired temperature
REMEDY
●
Hardware should be checked
1179 Glue cleaning pad finished
CAUSE
●
Glue cleaning pad finished
REMEDY
●
Insert new paper
1180 Z-axis, GU1: While raising, Bero not activated
CAUSE
●
Z axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
●
Check the mechanism; check the bero; check the incremental transducer.