19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 132
1167 GU: Error while setting new cartridge
CAUSE
An error occurred while a command was being sent to the GU that a new cartridge had been
inserted.
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshooting
1168 GU: Error while reading actual temperature
CAUSE
While the actual temperature was being requested for the GU an error occurred
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshooting
1169 GU: Error during Switch on continuous glueing
CAUSE
While the continuous glueing of the GU was being switched on an error occurred
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshooting
1170 GU: Error during Switch off continuous glueing
CAUSE
While the continuous glueing of the GU was being switched off an error occurred
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshooting
1171 Error during Send
INI data
to GU
CAUSE
An error occurred while .ini data was being sent to the GU
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshooting
1172 GU: Error during Send process data
CAUSE
An error occurred while process data was being sent to the GU.
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshooting
1173 GU: Error during Receive process data
CAUSE
An error occurred while process data was being received by the GU.
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshooting
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 133
1174 WARNING: Fill cartridge before next PCB
CAUSE
Bero for "Empty cartridge" triggered; not enough glue left to glue the next board
REMEDY
Change cartridge and confirm
1175 Cartridge empty; PCB will not be processed
CAUSE
This was preceded by error 1174 and the cartridge was still not changed
REMEDY
Change cartridge and confirm
1176 Cleaning process must be started
CAUSE
One of the cleaning conditions has occurred. Not an error
REMEDY
The machine cleans itself automatically
1177 GU: Software error in RIO call
CAUSE
Software error
REMEDY
AUT 5 BSM 14 Development should be notified
1178 Actual temperature does not reach desired temperature
CAUSE
Glueing parameter controller did not reach the desired temperature
REMEDY
Hardware should be checked
1179 Glue cleaning pad finished
CAUSE
Glue cleaning pad finished
REMEDY
Insert new paper
1180 Z-axis, GU1: While raising, Bero not activated
CAUSE
Z axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 134
1181 Z-axis, GU2: While raising, Bero not activated
CAUSE
Z axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1182 Z-axis, GU3: While raising, Bero not activated
CAUSE
Z axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1183 Z-axis, GU1: When axis at bottom, Bero not released
CAUSE
Z axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1184 Z-axis, GU2: When axis at bottom, Bero not released
CAUSE
Z axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1185 Z-axis, GU3: When axis at bottom, Bero not released
CAUSE
Z axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1186 Pressure build-up faulty
CAUSE
The glue cartridge is missing; the compressed air supply to the dispenser unit is inadequate;
the valve (actuation) is defective
REMEDY
Insert cartridge; check the compressed air supply, hoses, valve
1187 Pressure reduction faulty
CAUSE
The venting valve (actuation) is defective
REMEDY
Check the valve and hoses