00191025-01 - 第721页
19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 134 1181 Z-axis, GU2: W hile raising, Bero not activate d CAUSE ● Z axis is not moving upwards (sl…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 133
1174 WARNING: Fill cartridge before next PCB
CAUSE
●
Bero for "Empty cartridge" triggered; not enough glue left to glue the next board
REMEDY
●
Change cartridge and confirm
1175 Cartridge empty; PCB will not be processed
CAUSE
●
This was preceded by error 1174 and the cartridge was still not changed
REMEDY
●
Change cartridge and confirm
1176 Cleaning process must be started
CAUSE
●
One of the cleaning conditions has occurred. Not an error
REMEDY
●
The machine cleans itself automatically
1177 GU: Software error in RIO call
CAUSE
●
Software error
REMEDY
●
AUT 5 BSM 14 Development should be notified
1178 Actual temperature does not reach desired temperature
CAUSE
●
Glueing parameter controller did not reach the desired temperature
REMEDY
●
Hardware should be checked
1179 Glue cleaning pad finished
CAUSE
●
Glue cleaning pad finished
REMEDY
●
Insert new paper
1180 Z-axis, GU1: While raising, Bero not activated
CAUSE
●
Z axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
●
Check the mechanism; check the bero; check the incremental transducer.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 134
1181 Z-axis, GU2: While raising, Bero not activated
CAUSE
●
Z axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
●
Check the mechanism; check the bero; check the incremental transducer.
1182 Z-axis, GU3: While raising, Bero not activated
CAUSE
●
Z axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
●
Check the mechanism; check the bero; check the incremental transducer.
1183 Z-axis, GU1: When axis at bottom, Bero not released
CAUSE
●
Z axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
●
Check the mechanism; check the bero; check the incremental transducer.
1184 Z-axis, GU2: When axis at bottom, Bero not released
CAUSE
●
Z axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
●
Check the mechanism; check the bero; check the incremental transducer.
1185 Z-axis, GU3: When axis at bottom, Bero not released
CAUSE
●
Z axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
●
Check the mechanism; check the bero; check the incremental transducer.
1186 Pressure build-up faulty
CAUSE
●
The glue cartridge is missing; the compressed air supply to the dispenser unit is inadequate;
the valve (actuation) is defective
REMEDY
●
Insert cartridge; check the compressed air supply, hoses, valve
1187 Pressure reduction faulty
CAUSE
●
The venting valve (actuation) is defective
REMEDY
●
Check the valve and hoses

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 135
1188 Glue spot check: error during meas. description generation
CAUSE
●
Target diameter of the glue spots in the VKL file are outside the permitted range (0 < or < 3 mm)
Camera data (MA data) conversion factor pixels => µm erroneous
REMEDY
●
Check data
1189 Glue spot check: error during measurement description loading
CAUSE
●
Transmission error with the MVS vision system; possibly incorrect Eprom version
REMEDY
●
Check Eprom version
1190 Glue spot check: error during visualization of results
CAUSE
●
Transmission error with MVS vision system
REMEDY
●
Check vision system
1191 Glue spot check: measurements start error
CAUSE
●
Transmission error with MVS vision system
REMEDY
●
Check vision system
1192 Glue spot check: error in measurement results
CAUSE
●
Possibly incorrect Eprom version; otherwise software error
REMEDY
●
Check Eprom version
1193 Glue spots too large for calculating volume adaption
CAUSE
●
The size of glue spots is outside the control range for volume adaption (-5....+5); incorrect gluing sta-
tion configuration
REMEDY
●
Check process parameters: nozzle diameter, spacer, temperature;
check gluing station configuration