SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 1 35 1188 Glue spot check: error during meas . description generation CAUSE ● Target di ameter o f …

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 134
1181 Z-axis, GU2: While raising, Bero not activated
CAUSE
Z axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1182 Z-axis, GU3: While raising, Bero not activated
CAUSE
Z axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1183 Z-axis, GU1: When axis at bottom, Bero not released
CAUSE
Z axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1184 Z-axis, GU2: When axis at bottom, Bero not released
CAUSE
Z axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1185 Z-axis, GU3: When axis at bottom, Bero not released
CAUSE
Z axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1186 Pressure build-up faulty
CAUSE
The glue cartridge is missing; the compressed air supply to the dispenser unit is inadequate;
the valve (actuation) is defective
REMEDY
Insert cartridge; check the compressed air supply, hoses, valve
1187 Pressure reduction faulty
CAUSE
The venting valve (actuation) is defective
REMEDY
Check the valve and hoses
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 135
1188 Glue spot check: error during meas. description generation
CAUSE
Target diameter of the glue spots in the VKL file are outside the permitted range (0 < or < 3 mm)
Camera data (MA data) conversion factor pixels => µm erroneous
REMEDY
Check data
1189 Glue spot check: error during measurement description loading
CAUSE
Transmission error with the MVS vision system; possibly incorrect Eprom version
REMEDY
Check Eprom version
1190 Glue spot check: error during visualization of results
CAUSE
Transmission error with MVS vision system
REMEDY
Check vision system
1191 Glue spot check: measurements start error
CAUSE
Transmission error with MVS vision system
REMEDY
Check vision system
1192 Glue spot check: error in measurement results
CAUSE
Possibly incorrect Eprom version; otherwise software error
REMEDY
Check Eprom version
1193 Glue spots too large for calculating volume adaption
CAUSE
The size of glue spots is outside the control range for volume adaption (-5....+5); incorrect gluing sta-
tion configuration
REMEDY
Check process parameters: nozzle diameter, spacer, temperature;
check gluing station configuration
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 136
1194 Glue spot check: no evaluation due to low qual.
CAUSE
The shape or contrast of the glue spot was not good enough for the glue spot check.
REMEDY
Check the gluing needle (defective, dirty).
The glue is leaving threads (check glue temperature)
Color of the glue is not satisfactory (for example, white glue), leading to poor contrast with the glue
scraper roller where the glue spot check is made.
1195 Glue spots too small for calculating volume adaption
CAUSE
The size of glue spots is outside the control range for volume adaption (-5....+5); incorrect gluing sta-
tion configuration
REMEDY
Check process parameters: nozzle diameter, spacer, temperature;
check gluing station configuration