Error Code List.pdf - 第30页
RL1 31 ERROR CODE LIST 2.4 Errors DA8EEC- 91-210- A0 2.4- 7 1700 XY i n terlo ck (Rig ht rail ) DESCRI PTIO N Int er l ock was detecte d betwee n XY table and right rail . CAUSE W hile XY tab le is moving righ t rail tra…

RL131
ERROR CODE LIST
2.4 Errors
DA8EEC-91-210-A0
2.4-6
1304
Pre Process Production End
DESCRIPTION
Ending signal from preceding process has been detected.
CAUSE
Preceding machine is sending the signal of ending the production.
SOLUTION
Turn OFF the Ending signal from preceding process.
NOTE
1306
Data check
DESCRIPTION
Data do not satisfy the production condition.
CAUSE
Data condition required for production is insufficient.
SOLUTION
Enter the Data modification mode and press the data check key to confirm NG data items. And then change data.
NOTE
1310
Driver condition
DESCRIPTION
Trouble is found in the servo driver.
CAUSE
Servo driver alarm signal was detected.
SOLUTION
Cancel the driver error.
NOTE
1314
Safety relay
DESCRIPTION
Safety relay has not been properly reset.
CAUSE
There are some troubles in the safety relay.
SOLUTION
Replace the safety relay.
NOTE
1316
Thermal trip (Pump)
DESCRIPTION
Thermal switch for the Pump has detected overcurrent.
CAUSE
Thermal switch for the Pump was activated due to overcurrent.
SOLUTION
Reset the thermal relay.
NOTE
1516
Driver communication error
DESCRIPTION
Communication with an axial driver went wrong.
CAUSE
Communication error between the NC board and driver was detected.
SOLUTION
Call the Servicing Department of our company.
NOTE

RL131
ERROR CODE LIST
2.4 Errors
DA8EEC-91-210-A0
2.4-7
1700
XY interlock (Right rail)
DESCRIPTION
Interlock was detected between XY table and right rail.
CAUSE
While XY table is moving right rail traverse limit sensor (80000:bit0) was detected.
SOLUTION
Please confirm whether right rail is down position. Please confirm right rail traverse limit sensor.
NOTE
1701
XY interlock (Left rail)
DESCRIPTION
Interlock was detected between XY table and left rail.
CAUSE
While XY table is moving left rail traverse limit sensor (80040:bit4) was detected.
SOLUTION
Please confirm whether left rail is down position. Please confirm left rail traverse limit sensor.
NOTE
1702
Auto width interlock
DESCRIPTION
Auto width interlock was detected.
CAUSE
Interlock signal was input while auto width running.
It tried to operate auto width axis with the interlock signal input.
SOLUTION
Please confirm interlock signal. Interlock signal to which the auto width refers is as follows.
<Interlock signal> PCB detection 1 (80000:bit2) PCB detection 2 (80000:bit3) PCB detection 3 (80040:bit6) PCB
detection 4 (80040:bit7) XY table PCB detection (80003:bit0)
Right belt motor output (Positive rotation 80020:bit2) (Reverse rotation 80020:bit3)
Left belt motor output (Positive rotation 80060:bit2) (Reverse rotation 80060:bit3)
Safety cover (80581:bit0/bit1/bit2/bit3) Emergency input (80581:bit4/bit5/bit6/bit7)
XY axis origin (NC origin) H axis origin (M.ORG)
NOTE
1703
Air down interlock
DESCRIPTION
Air pressure was down.
CAUSE
Air down sensor (80002:bit5) was detected while machine was running.
SOLUTION
Please confirm whether the air pressure is correct.
NOTE
1705
Handle interlock
DESCRIPTION
Pushing H axis rotation wheel was detected.
CAUSE
H axis wheel detection (800C3:bit2) was detected while H axis was running.
SOLUTION
Please return H axis rotation wheel to original position.
NOTE

RL131
ERROR CODE LIST
2.4 Errors
DA8EEC-91-210-A0
2.4-8
1708
Power failure interlock
DESCRIPTION
The power failure was detected while the machine was running.
CAUSE
Power failure (80580:bit7) was detected while the machine was running.
SOLUTION
Please turn power failure reset signal (805A0:bit7) on and off by the [Output check] of [Machine adjustment] to reset
power failure.
NOTE
1710
θA axis plus overrun interlock
DESCRIPTION
The plus overrun interlock of the θA axis was detected.
CAUSE
θA plus overrun (80041:bit4) was detected while the θA axis was running. θA axis is located near mechanical
stopper.
SOLUTION
Please confirm θA plus overrun detection. Please confirm θA axis position.
NOTE
1711
θA axis minus overrun interlock
DESCRIPTION
The minus overrun interlock of the θA axis was detected.
CAUSE
θA minus overrun (80041:bit6) was detected while the θA axis was running. θA axis is located near mechanical
stopper.
SOLUTION
Please confirm θA minus overrun detection. Please confirm θA axis position.
NOTE
1714
X axis plus/minus overrun interlock
DESCRIPTION
The plus/minus overrun interlock of the X axis was detected.
CAUSE
X plus/minus overrun (80582:bit5) was detected while the X axis was running. X axis is located near mechanical
stopper.
SOLUTION
Please confirm X plus/minus overrun detection. Please confirm X axis position.
NOTE
1715
Y axis plus/minus overrun interlock
DESCRIPTION
The plus/minus overrun interlock of the Y axis was detected
CAUSE
Y plus/minus overrun (80582:bit4) was detected while the Y axis was running. Y axis is located near mechanical
stopper.
SOLUTION
Please confirm Y plus/minus overrun detection. Please confirm Y axis position.
NOTE
1718
Ring IO communication interlock
DESCRIPTION
RING IO communication interlock was detected.
CAUSE
There is a possibility of coming off and the disconnection of the RING communication optical cable.
SOLUTION
Please confirm the RING communication optical cable.
NOTE