Error Code List.pdf - 第46页
RL1 31 ERROR CODE LIST 2.4 Errors DA8EEC- 91-210- A0 2.4- 23 1894 USB4 ove rcurrent al arm DESCRI PTIO N The U SB4 ove r current alarm of C PU board was detected. CAUSE There i s a pos sibility t hat CPU boar d is ou t o…

RL131
ERROR CODE LIST
2.4 Errors
DA8EEC-91-210-A0
2.4-22
1888
LVDS over current alarm
DESCRIPTION
The LVDS overcurrent alarm of CPU board was detected.
CAUSE
There is a possibility that CPU board is out of order.
SOLUTION
Please contact our service section.
NOTE
1889
DVI overcurrent alarm
DESCRIPTION
The DVI overcurrent alarm of CPU board was detected.
CAUSE
There is a possibility that CPU board is out of order.
SOLUTION
Please contact our service section.
NOTE
1890
USB0 overcurrent alarm
DESCRIPTION
The USB0 overcurrent alarm of CPU board was detected.
CAUSE
There is a possibility that CPU board is out of order.
SOLUTION
Please contact our service section.
NOTE
1891
USB1 overcurrent alarm
DESCRIPTION
The USB1 overcurrent alarm of CPU board was detected.
CAUSE
There is a possibility that CPU board is out of order.
SOLUTION
Please contact our service section.
NOTE
1892
USB2 overcurrent alarm
DESCRIPTION
The USB2 overcurrent alarm of CPU board was detected.
CAUSE
There is a possibility that CPU board is out of order.
SOLUTION
Please contact our service section.
NOTE
1893
USB3 overcurrent alarm
DESCRIPTION
The USB3 overcurrent alarm of CPU board was detected.
CAUSE
There is a possibility that CPU board is out of order.
SOLUTION
Please contact our service section.
NOTE

RL131
ERROR CODE LIST
2.4 Errors
DA8EEC-91-210-A0
2.4-23
1894
USB4 overcurrent alarm
DESCRIPTION
The USB4 overcurrent alarm of CPU board was detected.
CAUSE
There is a possibility that CPU board is out of order.
SOLUTION
Please contact our service section.
NOTE
1895
USB5 overcurrent alarm
DESCRIPTION
The USB5 overcurrent alarm of CPU board was detected.
CAUSE
There is a possibility that CPU board is out of order.
SOLUTION
Please contact our service section.
NOTE
1896
CF access impossible
DESCRIPTION
It was not able to access CF on CPU board.
CAUSE
There is a possibility that CPU board is out of order.
SOLUTION
Please contact our service section.
NOTE
1897
Power ON first Safety Stop
DESCRIPTION
Machine is under safety stop condition.
CAUSE
Whenever machine was turned on, it becomes safety stop condition.
SOLUTION
Please continue the operation after press return button to close error screen.
NOTE
1900
Maintenance mode switching error
DESCRIPTION
Production menu was selected during maintenance.
CAUSE
Production menu is restricted during maintenance.
SOLUTION
Release the maintenance mode.
NOTE
1901
Maintenance switch abnormal
DESCRIPTION
Maintenance switch was detected abnormally.
CAUSE
Maintenance switch was detected with the cover closed.
(1) Cover switch has been sort-circuited intentionally.
(2) Faulty maintenance switch
SOLUTION
Do not short-circuit the cover switch intentionally.
Check the detected state of the maintenance switch.
NOTE

RL131
ERROR CODE LIST
2.4 Errors
DA8EEC-91-210-A0
2.4-24
1920
Feeder install error
DESCRIPTION
The feeder installation is abnormal.
CAUSE
The feeders may not have been installed properly.
SOLUTION
Check the installation condition of the feeders.
NOTE
2003
PCB carry in restart cancel (right rail belt)
DESCRIPTION
The restart of the PCB carrying in was canceled.
CAUSE
When the carrying in operation was restarted by the safety stop release, PCB was detected at the right rail exit.
SOLUTION
Please restart the operation after confirming PCB on a right rail.
NOTE
2011
PCB carry in restart cancel (right rail exit)
DESCRIPTION
The restart of the PCB carrying in was canceled.
CAUSE
When the carrying in operation was restarted by the safety stop release, PCB was detected at the right rail exit.
SOLUTION
Please restart the operation after confirming PCB on a right rail.
NOTE
2012
PCB carry in restart cancel (right rail exit)
DESCRIPTION
The restart of the PCB carrying in was canceled.
CAUSE
When the carrying in operation was restarted by the safety stop release, PCB was detected at the right rail exit.
SOLUTION
Please restart the operation after confirming PCB on a right rail.
NOTE
2052
PCB carry out restart cancel (left rail belt)
DESCRIPTION
The restart of the PCB carrying out was canceled.
CAUSE
When the carrying out operation was restarted by the safety stop release, PCB was detected at the left rail exit.
SOLUTION
Please restart the operation after confirming PCB on a left rail.
NOTE
2079
PCB carry out restart cancel (left rail exit)
DESCRIPTION
The restart of the PCB carrying out was canceled.
CAUSE
When the carrying out operation was restarted by the safety stop release, PCB was detected at the left rail exit.
SOLUTION
Please restart the operation after confirming PCB on a left rail.
NOTE