00194614-08 Trainingsdoku. SG X-Serie_X4i SW70x (AL2)_EN - 第143页

Communication and Control Board IDs Re ading the Board IDs out of the EEPROM 143 Student Guide SIPLACE X-Serie and X4I SW70x (AL2) Assembly ID 01 is digita l pressure control valve Assembly ID 02 is analog pressur e cont…

100%1 / 522
Communication and Control
Reading the Board IDs out of the EEPROM Board IDs
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 142
Head interface board type recognition ID 01
The ID will appear in the memory cell 12, the ID 01 for the head interface C500.
Head adapter board type recognition ID 22 for the C&P20A head
C&P20A board ID 30
C&P20A board ID 31 vacuum sensor, hold circuit
Communication and Control
Board IDs Reading the Board IDs out of the EEPROM
143 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Assembly ID 01 is digital pressure control valve
Assembly ID 02 is analog pressure control valve
Device number pressure control valve digital C&P20A
Reading and Writing the Bo ard IDs wi th CAN Commands
4.6.2.2 Reading and Writing the Board IDs with CAN Commands
Switch off the machine.
Connect the service laptop to the machine CAN bus at PA1 and/or PA2.
Make sure that the cable is connected at channel 1 for PA1 and at channel 2 for PA2 of the Kvaser
card.
Switch on the machine
Start the Caccia software and check the machine configuration in Caccia.
Doubleclick on the Open Subsystem Control Center.
Select Get Versions.
All available subsystems will be shown with their firmware versions and their CAN IDs.
NOTICE
The digital pressure control valve (C&P20A) and the analog pressure control valve (Twin head)
do not have a board ID or it is currently 00.
NOTICE
Both pressure control valves will be recognized via a device number. This assembly ID is at
memory cell 14 in the EEPROM.
Change Properties Change Machine
Configuration
Open Subsystem Control
Center
Communication and Control
Reading the Board IDs out of the EEPROM Board IDs
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 144
Subsystem control center
In the Subsystem control center window, search for the subsystem (TQM module), which you
want to access, in order to then use the correct CAN ID in the network window.
This means, to check the head interface, head adapter and intermediate distributor use the CAN ID
300 for gantry 1 or 308 for gantry 2 and so on.
Perform a BIOS download to the TQM module, so that you are sure that only the BIOS is running.
Open the network 1 for PA 1 and network 2 to for PA 2.
With the correct CAN ID and the BIOS commands, you can now write the correct board ID in the
EEPROM.
NOTICE
Always use the IDs which are shown in the subsystem control window, when you click on
GET VERSION or ACTIVATE IDs .
e.g. Head Processor
Gantry 1 --> 300
Gantry 2 --> 308
Gantry 3 --> 310
Gantry 4 --> 318.
Exception: If you don‘t received a message from a subsystem, so you can try to work with
"Standard ID‘s" e.g.Head processor:
Gantry 1 --> 304
Gantry 2 --> 30c
Gantry 3 --> 314
Gantry 4 --> 31c,
required when two board IDs are missing.
NOTICE
To write the board IDs with CAN commands, make sure that just the BIOS is running on the
TQM module.