00194614-08 Trainingsdoku. SG X-Serie_X4i SW70x (AL2)_EN - 第178页
Energy and Compressed Air Supply Safety Valve X60 Pneumatic System Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 178 Safety Valve X60 5.3.6 Safety Valve X60 S a fe ty va lv e f o r c on tr ol li ng th e c o mp re ss …

Energy and Compressed Air Supply
Pneumatic System Proportional Valve, Proportional Regulator X58
177 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Proportional Valve, Proportional Regulator X58
5.3.5 Proportional Valve, Proportional Regulator X58
When switching the machine on at the main switch, air is supplied to all placement heads.
After the reference run is performed, the air can be switched off by the software after a certain time (as
standard 2 min.) and air will stop flowing through the vacuum system of the placement heads.
The X58 proportionate valve regulates the compressed air to 4.8 +0.1 bar for the placement head.
Included within this regulator block is a pressure sensor which monitors the outgoing air pressure. If the
pressure falls below 4.5 bar, the CAN bus will issue a signal. The valve is controlled by relay K2, located
in section 2, main distributor.
proportional valve X59 ON/OFF process

Energy and Compressed Air Supply
Safety Valve X60 Pneumatic System
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 178
Safety Valve X60
5.3.6 Safety Valve X60
Safety valve for controlling the compressed air for transport and tape cutter. The compressed air supply
for these modules is only present after the start button has been pressed and all safety requirements
have been fulfilled (safety loop closed).
Safety valve for tape cutter
Main distributor (sector 2) relay K2
Legend
1. Relay K2

Energy and Compressed Air Supply
Pneumatic System Compressed Air Supply to Tape Cutter
179 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Compress ed Air Supply to Tape C utter
5.3.7 Compressed Air Supply to Tape Cutter
Compressed A ir Supply to the Conveyo r
5.3.8 Compressed Air Supply to the Conveyor
As with the tape cutters, the compressed air supply to the conveyors is switched via the safety valve.
This means that the safety valve is only switched via the control ON function once all safety circuits have
closed and made contact.
In the conveyor, the lifting table and the width adjustment driver are supplied with compressed air.
Compressed Air Supply to the Docking Unit (Changeover Table)
5.3.9 Compressed Air Supply to the Docking Unit (Changeover Table)
Compressed Air Supply to Tape Cutter
Legend:
1. Cylinder for moving (40 mm) the cut edge
2. Adjustment valve for the cylinder concerned
3. 5/2 way valve
4. Air supply - 5 bar switched via SSK (if SSK enabled)
Compressed Air Supply to the Docking Unit (Changeover
Table)
Legend:
1. Cylinder for docking unit, table movement 43 mm
2. Adjustable regulator on cylinder
3. Table release cylinder ("extend") 10 mm movement
(lift)