Set the position of the stopper bar (by moving it in its fixing holes), if the behavior described above
is not observed. If necessary, remove the covers behind the doors.
Check on tower 1 that a WTC XL with 25 mm-high components can be transported without colliding
with the stopper bar. If necessary, correct the position of the stopper bar.
Checking and setting the stopper bars, bottom
Checking and setting the stopper bars, bottom
Cassette g uide rails
13.3.3.3 Cassette guide rails
Tools and Equipment
Tools and Equipment
1 set of Allen keys
Preparat ions
Preparations
Empty the MTC2 completely (see the User Manual).
Prepare an empty cassette XL.
Guide rails, bottom
Move the doors fully down
Remove the side covers
Set the position of the guide rails until they are
approx. 0.5 through 1mm away from the WTCs.
WARNING! The stopper bar and guide rail must
under no circumstances touch the WTCs!
Legend
1. Guide rails
2. Fastening screws
NOTICE
An empty cassette is needed to set the cassette guide rails.
MTC2
Adjustments Lifting Axes MTC2 Calibration and Settings
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 480
Setting the cassette g uide rails
Setting the cassette guide rails
Move the lifting axis into the refill position for cassette 1-> check the zero offset.
Loosen the securing screws on both cassette guide rails.
Tighten the securing screws of the inner cassette guide rail at the position in which the cassette can
still be inserted into the tower smoothly.
Position the second cassette guide rail by means of the cassette parallel to the first cassette, so that
the cassette can be moved easily but without any lateral play. Tighten the securing screws here as
well.
Check the setting of the other refill positions. -> "Check the refill positions“). If necessary, correct the
position of the cassette guide rails which has been set.
Setting the cassette guide rails
Legend
1. Cassette XL in the refill position for tower 1
2. Cassette in the refill position for tower 2
3. Cassette guide rails for tower 1
4. Cassette guide rails for tower 2
MTC2
MTC2 Calibration and Settings Adjustments feed axes
481 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Adjustments feed axes
13.3.4 Adjustments feed axes
Overview of the feed axes (cover plates and belt covers removed)
Legend
Belt tensio n
13.3.4.1 Belt tension
Tools and Equipment
Tools and Equipment
Belt frequency measurement device (inductive)
2 belt tension strips
1 set of Allen keys
1 set of open-ended wrenches
1 Feed axis, tower 1 5 Toothed belt
2 Feed axis, tower 2 6 Disengaging mechanisms
3 Servo motors of the feed axes 7 Driver
4 Drive belt