00194614-08 Trainingsdoku. SG X-Serie_X4i SW70x (AL2)_EN - 第504页
MTC2 Error messages issued via the station Masterdrives Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 504 Error mess ages issue d via the station 13.4.6 Error messages i ssued via the stat ion Alarms and faults on th…

MTC2
Masterdrives Downloading Parameter Sets
503 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
Upload parameter set
Download parameter set:
13.4.5.5 Download parameter set:
► Select FILE --> Download --> Save EEPROM
► Switch the MTC OFF and then ON again. Start the reference run.
NOTICE
Before you start the download, the master drive should be reset to factory defaults (see 13.4.3).
CAUTION
The axis concerned must not be subject to position control!
NOTICE
TIP
There are two ways of deactivating position control:
- Open the MTC door or
- Switch the MTC on and do not perform a reference run of the MTC.

MTC2
Error messages issued via the station Masterdrives
Student Guide SIPLACE X-Serie and X4I SW70x (AL2) 504
Error messages issued via the station
13.4.6 Error messages issued via the station
Alarms and faults on the master drive
▪ A140, A141: Axis blocked, does not move easily, check and remove any obstruction.
▪ FF01: Time overrun
▪ FF04: A fault has occurred during the RAM test.
▪ FF05: A fault has occurred during the EPROM test.
▪ FF13: A version conflict has occurred between the firmware and the hardware.
▪ F002: The monitoring time has expired. The DC intermediate circuit voltage has not reached the
setpoint (3s) (can be ignored).
▪ F006: Intermediate circuit voltage too high. If this fault occurs during the startup phase: Press the
SIPLACE start button.
During operation: Contact the SIPLACE service team.
▪ F008: The lower limit value (76%) was undershot (can be ignored).
Press the SIPLACE start button.
▪ F011: Short circuit
▪ F015: Axis blocked, does not move easily during reference run
▪ F020: Motor temperature monitoring triggered.
▪ F021: Motor blocked, does not move easily. (I2t monitoring for the motor)
Downloading Parameter Sets
NOTICE! !
Select Save on EEPROM
CAUTION! If errors are counted in field E:(Error)
when you first start the download, abort the download
immediately and try it again.
NOTICE
Art und Quelle der Gefahr
Alarm messages will begin with „Axxx“. An alarm cannot be acknowledged.
It is automatically deleted once the cause has been eliminated.
NOTICE
Art und Quelle der Gefahr
Fatal errors will begin with „FFxx“. Fatal errors are serious hardware or software errors which
no longer permit normal operation of the Master drives. They only appear on the PMU in the
form "FF<No>". The software is re-booted by actuating any key on the PMU.
NOTICE
Art und Quelle der Gefahr
Fault messages will begin „Fxxx“. If a fault message is not reset before the electronic supply
voltage is switched off, then the fault message will be present again when the electronic supply
is switched on again.
MTC2
Masterdrives Error messages issued via the station
505 Student Guide SIPLACE X-Serie and X4I SW70x (AL2)
▪ F023: Overtemperature master drives:
Ventilation locked, wire break at sensor.
▪ F035: Axis in the limit switch
▪ F041: A fault has occurred during the storage of values in the EEPROM.
▪ F051: Fault at resolver or cable disconnected.
▪ F082: Telegram fault - no new process data received. Replace the assembly.
▪ F085: A fault has occurred during initialization of the controller assembly in the master drives.
See also