Edition 1 .0 IPS Adjustment for V arious H ead T ypes on the Module <V12 h ead> FK - 9F50 -74-0E 4-2 FUJI CORPORA TION 2. Attach t he jigs to holder s B and L on the head (AA63T0*) and then att ach the head t o the…

100%1 / 172
Edition 1.0 IPS Adjustment for Various Head Types on the Module
<V12 head>
FK-9F50-74-0E
4-1
FUJI CORPORATION
Chapter 4 – V12 head IPS adjustment
Camera position adjustment, current value (grayscale value)
adjustment, and area check
Required jigs
Drawing No.
QTY
Photo
2AGKHJ0132**
(New draw in g N o.)
AA63T0**
(Old drawi ng N o.)
2
Requir ed software
Name
MotionTool.mini
Motion Adjustment T ool
Inspection item
Tolerance
LED current adjustm ent
Adjust the current value so that GR = 95 or above and GL = 95
or above (GR and GL grayscale values should be in the
range 95~250. Target is 1 20) .
CURRENT = 24 mA or less
Camera resolution ch eck
L: X = 92~ 108
L: Z = 92~108
Center val ue
R: Xs = 380~400
(Target: 390) , Zp = 310~ 330 (Target: 320)
L: Xp = 80~ 100
(Target: 90), Zp = 310~ 330 (Target: 320)
Tilt
R: dX = 0~9 ( Target: 0) , dZ = 0~ 9 ( Target: 0)
L: dX = 0~ 9
(Target: 0), dZ = 0~9 (Target: 0)
Preparation on the module
1. Remov e t he covers
CONFIDENTIAL
Edition 1.0 IPS Adjustment for Various Head Types on the Module
<V12 head>
FK-9F50-74-0E
4-2
FUJI CORPORATION
2. Attach the jigs to holders B and L on the head (AA63T0*) and then attach the head to
the module.
To adjust the IPS camera position, it is necessary to move the head R-axis to the
holder A calibratio n data position.
The follow ing st eps explain how t o check the servo counter using MotionTool(Min i).
3. After the machine wakes up, press [Start] button and then press [Cycle stop] button
immediately. At that time, ma ke sur e t he holder A has been moved to the front.
4. Startup MotionTool(Mini).
5. Enter the IP address of the base and t he module number, and then click [Connect].
6. Select [Wake] - [Automatic recognition] - [OK] to start up the servo. After about 10
seconds, t he cur r ent servo counter for each axis w ill be di splayed.
7. The Axis 3 is the R-axis servo counter. Record this value. (Reference value: 30000 ±
500 pulses) Keep this position to adju st the IPS cam er a position.
Z-axis
R-axis
Q-axis
CONFIDENTIAL
Edition 1.0 IPS Adjustment for Various Head Types on the Module
<V12 head>
FK-9F50-74-0E
4-3
FUJI CORPORATION
The follow ing st eps explain how to chec k the s er vo counter using Motion Adjustment Tool.
8. After the machine wakes up, press [Start] button and then press [Cycle stop] button
immediately.
9. Start up Motion Adjustment Tool.
10. Select [Communication] [Connect].
Select