TR7500_Series_Software_v29_En - 第182页

Test Research Inc. 160 TR7500 Series User Guid e –Softwa re v.2.9.0 6.7 FOV Ge nerate Fields of View [FOVs] are used to de fine inspection areas . One component may have many FOVs; e.g. one for each pin. Each FOV may hav…

100%1 / 330
Test Research Inc.
TR7500 Series User Guide –Software v.2.9.0 159
6.6 Library
6.6.1 Verify
Figure 265: Library Verify Tab
6.6.1.1 Component Library
Select to enter the [Tune] field.
6.6.1.2 Name Index
Select to open [Name Index] window.
6.6.2 Merge
Figure 266: Library Merge Tab
Merge means for all components on a PCB the system will copy all inspection boxes to every
component depending on the type.
6.6.2.1 Merge
Merge the selected type.
6.6.2.2 Merge All
Merge all types.
Test Research Inc.
160 TR7500 Series User Guide –Software v.2.9.0
6.7 FOV Generate
Fields of View [FOVs] are used to define inspection areas. One component may have many
FOVs; e.g. one for each pin. Each FOV may have many different inspection functions.
Figure 267: FOV Function Tab
6.7.1 Generate
Press [Generate] then the system will recalculate the deployment of FOVs.
6.7.2 Release
Clear the data calculated previously..
6.7.3 Capture Whole Image
Press to capture FOV images according to the calculation.
Test Research Inc.
TR7500 Series User Guide –Software v.2.9.0 161
6.8 Motion Controller
1
2
3
4
5
6
7
Figure 268: Motion Control Outlook & Functions
(1). [Distance Scaling]Choose the moving magnification of step.
(2). [Step]Input the moving scale (pulse) of X-Y Table.
(3). [X, Y] Refers to the coordinates of the camera on X-axis and Y-axis.
(4). [Lock/Unlock] Press to toggle lock/unlock of X-Y Table motion.
(5). Direction Arrows Press to move Table in the corresponding direction. For
example, press
to move the camera to the front-left side with a specific pulse
([Step] multiplied by [Scaling]).
(6). Central Block Press to minimize the motion control box window. Double-click the
minimized tab to maximize the window.
(7). [Z] – Used only on specially modified systems.