Test Research Inc. 46 TR7500 Series User Guide – Software v.2.9.0 3.3.2 System Figure 81: Par ameter Tab – System Function 3.3.2.1 Halt Machine whe n Repeat Fail W he n there are repeated failures for a single inspection…

100%1 / 330
Test Research Inc.
TR7500 Series User Guide –Software v.2.9.0 45
3.3.1 User Mode
Figure 80: TR7500 Menu Bar – Parameter Tab/User Mode
3.3.1.1 Link to Repair Station?
Check to deliver the test result data to repair station. If the communication between
computers is broken the data will be saved in [C:\AOI_Repair_Data] folder. After the link is
normal the data will be transferred to the repair station automatically.
3.3.1.2 Link to Offline Editor?
Select this item to pass the result to Offline Editor. When [Offline=1] is set in the registry, it
means that the machine is an Offline Editor, the item turns to display [Link to Machine?]. See
Chapter
15 Offline Editor for more information about Offline Editor.
3.3.1.3 Operator Mode/Engineer Mode
Choose [Operator Mode] or [Engineer Mode] to operate the project. The initial setting is the
same as the previous user’s setting. Users cannot edit the project in [Operator Mode], they
can only open or inspect the project. The password of choosing [Engineer Mode] is [7100].
3.3.1.4 Link to Control Center
When [Link to Control Center] is enabled or disabled, the AOI main PC will send a “Reset”
signal to the PLC and Repair Station.
If the result is “PASS”, the board will be sent to the next station; if the result is “FAIL”, the
board will stay in the conveyor behind and wait for the confirmation from Repair Station. If
there is still a board in the conveyor behind after the next board is inspected completely, the
boards will be stuck. The system will send an alarm under the stuck situation until an
operator goes to solve it.
When the board is stuck, take the board away manually to test continuously. If the situation is
complicated, disable [Link to Control Center] then enable it again. The system will be reset
and you can try to inspect it again.
Test Research Inc.
46 TR7500 Series User Guide –Software v.2.9.0
3.3.2 System
Figure 81: Parameter Tab – System Function
3.3.2.1 Halt Machine when Repeat Fail
When there are repeated failures for a single inspection window the machine will pause, the
system will send an alarm, and the project will present a warning dialog. Under [Inline] mode,
the TR7500 will trigger the red light on the signal tower and sound an alarm. The operator
will have to confirm the result in order for the system to resume testing.
Figure 82: Set Halt Machine Test Count & Fail Message
3.3.2.2 Halt Machine when Fiducial Fail
When the project can’t find a fiducial mark, the motion of the table will pause and the project
will present a warning dialog.
Under [Inline] mode, the TR7500 will trigger the red light on the signal tower and sound an
alarm. The operator will have to confirm the result in order for the board to be sent to the exit..
Figure 83: Eject Board Message
Test Research Inc.
TR7500 Series User Guide –Software v.2.9.0 47
3.3.2.3 Halt Machine when Barcode Fail
The function is enabled when [Check Barcode] is set. If the barcode cannot be read by the
system, the motion of the table will pause and a warning dialog is displayed.
Figure 84: Barcode Fail Message
Under [Inline] mode, the TR7500 will trigger the red light on the signal tower and sound an
alarm. The operator will have to confirm the result in order for the system to resume testing.
If there is only one set of barcode, the system will show the [Key in Barcode] window in order
for user to enter the barcode manually.
Figure 85: Key In Barcode Message
3.3.2.4 Halt Machine when Abnormal Fail_board Rate
When the percentage of failed boards is over the specified percentage, the table motion will
pause and the project will display a warning dialog.
Figure 86: Set Board Fail Percentage and Fail Message
3.3.2.5 Inverse Pass/Fail Output Signal
Choose this function to change the signal of white and yellow lines in Port 2. Originally, when
the result is [PASS], the output signal is “short”; when the result is [FAIL], the output signal is
“open”. This function reverses the output signal. The password is [7100].