Test Research Inc. TR7500 Series User Guide – Software v.2.9.0 59 Figure 105 : Panel Paramet er – AutoLink Tab  [Enable Auto Link] – Enab le link with ICT/ATE machine.  [Test Prog ram Link Path] – Pass *.aip test prog …

100%1 / 330
Test Research Inc.
58 TR7500 Series User Guide –Software v.2.9.0
3.3.7 Panel Info Tab
Figure 103: Panel Parameter – Panel Info Tab
[Model Name] – The same as the original AOI file name. When you change the
project name, this isn’t changed.
[Board Side] – Set board to [Top] or [Bottom] side.
[Current Version] – Set current panel used component version. The current version
will appear in the top-right of the window’s title bar.
Figure 104: Project Version in Title Bar
[Lot No.] – Input the lot number of manufacture and it will become a search
condition in repair station.
[Board Out While Finish Scanning] – When the motion is finished, the board will be
sent out immediately.
3.3.8 Auto Link Tab
Set the path here for the auto link with ICT or ATE.
Test Research Inc.
TR7500 Series User Guide –Software v.2.9.0 59
Figure 105: Panel Parameter – AutoLink Tab
[Enable Auto Link] – Enable link with ICT/ATE machine.
[Test Program Link Path] – Pass *.aip test program data to ICT/ATE machine.
[Inspection Result Link Path] – Pass *.ifp inspection result data to ICT/ATE machine.
[ICT/ATE Input Link Path] – Pass *.afc inspection result data to ICT/ATE machine.
3.3.9 Repair Station Tab
Figure 106: Panel Parameter – Repair Station Tab
Test Research Inc.
60 TR7500 Series User Guide –Software v.2.9.0
[Path] – Set repair data saving path for repair station. Default setting is
[\\RepairPC\C\AOI_Repair_Data].
[Change Type to Part Number] – Choose this option to send [Type] data to repair
station in the [Hidden Type] field.
3.3.10 Offline Editor
Figure 107: Panel Parameter – Offline Editor Tab
[Path] – Set offline data save path for offline editor. Default is
[\\OfflinePC\C\AOI_Offline_Data].
[Max Fail Board Count] – This is the maximum inspecting number that the Offline
Editor can save. This means that the Offline Editor saves the latest 30 data only
when 30 is set in this field.
[Max Fail Image Count] – This is the maximum number of failed images that AOI
will transfer to Offline Editor. It means that AOI only transfers the previous 10 failed
images to Offline for every inspection when ‘10’ is set in this field.
See Chapter
15 Offline Editor for more information about Offline Editor.
3.3.11 Software Barcode
This is an optional function. After [Software Barcode] is enabled, the barcode can be read by
the system camera.
3.3.12 Assign Serial Code
The function is usually used where there is no barcode on the PCB. Assign the serial number
for the PCB. The serial number can show in the results dialog or translate to Repair Station.
Input the initial number first then press [OK] to start this function.