7.7 "Long Printed Circuit Board" Option
7.7.1 Purpose
The "Long printed circuit board" option allows you to process overlength printed circuit boards (up
to a length of 610mm). 7
7.7.2 Description
NOTE:
Please refer to the UNIX Line Computer Operating Guide and the Operating Guide for the
respective machine for a detailed description. 7
7
SIPLACE Software Guide SR.503.xx 8 New Functionality
Issue 12/01 EN 8.1 Software Version 503.01
103
8 New Functionality
8.1 Software Version 503.01
8.1.1 Placing 0201 Components
8.1.1.1 Purpose
For Typ 0201 components, solid-state pick-up has been implemented in order to minimize
pick-up errors. 8
8.1.1.2 Description
NOTE
Please refer to the Placing 0201 Components User Manual for a detailed description. 8
8.1.2 Component Sensor
8.1.2.1 Purpose
In addition to the vacuum check as Component presence control respectively, a Component sen-
sor has been introduced to function as an added optical control. This ensures that a on edge pi-
cked-up
component with varying component height and width is recognized. 8
8.1.2.2 Description
NOTE:
Please refer to the Online Help and the Component Sensor Operating Guide for a detailed de-
scription. 8
8 New Functionality SIPLACE Software Guide SR.503.xx
8.1 Software Version 503.01 Issue 12/01 EN
104
8.1.3 Synchronous Dual Transport
8.1.3.1 Purpose
Synchronous dual transport allows you to treat printed circuit boards that simultaneously
engage on both transport input conveyors as a logical printed board. This serves the purpose to
increase the transfer rate for cluster which requires a different pipette configuration. 8
8.1.3.2 Description
NOTE:
Please refer to the UNIX Line Computer Operating Guide and the Software Guide for the
respective machine for a detailed description. 8
8.1.4 Synchronous Restart
8.1.4.1 Purpose
If the connection between line computer and station is disrupted during running operation,
a dialog containing the corresponding information is displayed. After reboot of the line computer
under a running station, the communication between line computer and station is resumed,
and the dialog closes automatically. 8