SIPLACE S oftware Guide SR.503.xx 3 Graphical user i nterface Issue 12/01 E N 3.3 User interface - views and menus 35 Shut down computer... 3 All appl ications are clo sed withou t any files which may have been proc esse…

3 Graphical user interface SIPLACE Software Guide SR.503.xx
3.3 User interface - views and menus Issue 12/01 EN
34
Abort processing 3
This function allows you to abort certain operating steps such as feeder position recognition or
nozzle changes in the event of a machine stoppage (due to fatal error, or if the Stop button being
pressed). 3
Click the Abort processing menu item.
The current operation is aborted when you confirm the action in the displayed dialog box.
Continue processing 3
The assembly process, which is interrupted, for example, as a result of an error, is continued once
the cause of the error has been eliminated. 3
Click the Continue processing menu item (or the corresponding icon).
Start OIS (option) 3
This menu function starts the software for the "Operator Information System". The production data
acquisition system can be used to obtain information about the operating behavior of a complete
line or an individual station. 3
Start SIPLACE Pro (option) 3
This menu function starts the software for the "SIPLACE Pro". SIPLACE Pro makes it possible to
program and optimize SIPLACE placement machines and placement lines. 3
Configure SIPLACE Pro connection... (option) 3
In this dialog box, you can specify which computer is permitted to provide the current station com-
puter with data. 3
Switch to operating system... 3
You use this menu item to switch to the Windows operating system after entering your password.
From here, you can then subsequently return to the SIPLACE user interface. 3
NOTE
This menu option is not available at the "Operator" access level. 3
Click the Switch to operating system... menu item.
This shows the Windows user interface. The station computer software continues to run in the
background.
3

SIPLACE Software Guide SR.503.xx 3 Graphical user interface
Issue 12/01 EN 3.3 User interface - views and menus
35
Shut down computer... 3
All applications are closed without any files which may have been processed being saved and the
station computer is shut down. 3
Click the Shut down computer... menu item.
If you do not have a UPS in your computer, the following dialog box will be opened.
3
Fig. 3.3 - 1 " Shut down computer" without UPS dialog box
Click Yes if you want to terminate your work.
The station computer is shut down.
Switch off the machine at the main switch.
If you have a configured UPS in your computer, the following dialog box is opened.
3
Fig. 3.3 - 2 " Shut down computer" with UPS dialog box
You can switch off the machine at the main switch at any time.

3 Graphical user interface SIPLACE Software Guide SR.503.xx
3.3 User interface - views and menus Issue 12/01 EN
36
3.3.2.2 „View“ menu
The "View" menu contains the options for calling the placement functions, single functions and vi-
sion functions. It is also used to start the SITEST test program and call the view for running the
GEM functions. 3
Click the required menu option.
The screen display is switched to the corresponding view. From there you can carry out the
required functions.
NOTE
All the options in this menu can also be called by clicking the corresponding toolbar button (see
section 3.2.2) or by pressing the corresponding function key. If shortcuts have been defined, these
can also be used. 3
NOTE
The 3 menu options below belong to the group of placement functions. 3
Set-up F2 3
The setup for a feeder location is displayed in tabular form. It can be called separately for each of
the max. four locations. 3
Error F3 3
Errors are differentiated by type and each error type is presented in a separate table. You can call
separate tables for track errors, conveyor errors, machine errors and general errors.
The last error to have occurred is always displayed at the top of the table. Identical errors are cu-
mulated in the error counter ("#E" column). 3
Feeders F4 3
Here you can use a variety of functions to display and fill empty tracks for vibratory stick feeders
or to display and modify inventory levels for trays or to move the MTC (Matrix Tray Changer - Ma-
trix-tray changer (only for S-25 HM) on page 39) into transport position. 3