SIPLACE S oftware Guide SR.503.xx 3 Graphical user i nterface Issue 12/01 E N 3.3 User interface - views and menus 37 NOTE The foll owing 6 me nu opti ons belo ng to th e grou p of singl e functio ns. The single functio …

100%1 / 124
3 Graphical user interface SIPLACE Software Guide SR.503.xx
3.3 User interface - views and menus Issue 12/01 EN
36
3.3.2.2 „View“ menu
The "View" menu contains the options for calling the placement functions, single functions and vi-
sion functions. It is also used to start the SITEST test program and call the view for running the
GEM functions. 3
Click the required menu option.
The screen display is switched to the corresponding view. From there you can carry out the
required functions.
NOTE
All the options in this menu can also be called by clicking the corresponding toolbar button (see
section 3.2.2) or by pressing the corresponding function key. If shortcuts have been defined, these
can also be used. 3
NOTE
The 3 menu options below belong to the group of placement functions. 3
Set-up F2 3
The setup for a feeder location is displayed in tabular form. It can be called separately for each of
the max. four locations. 3
Error F3 3
Errors are differentiated by type and each error type is presented in a separate table. You can call
separate tables for track errors, conveyor errors, machine errors and general errors.
The last error to have occurred is always displayed at the top of the table. Identical errors are cu-
mulated in the error counter ("#E" column). 3
Feeders F4 3
Here you can use a variety of functions to display and fill empty tracks for vibratory stick feeders
or to display and modify inventory levels for trays or to move the MTC (Matrix Tray Changer - Ma-
trix-tray changer (only for S-25 HM) on page 39) into transport position. 3
3
SIPLACE Software Guide SR.503.xx 3 Graphical user interface
Issue 12/01 EN 3.3 User interface - views and menus
37
NOTE
The following 6 menu options belong to the group of single functions.
The single functions are used to execute specific actions following fatal errors as well as to set up
and test the machine since they allow you to address the various functional modules in a defined
manner. 3
Gantry 1 F5 3
This is used to call the single functions for Gantry 1. These can be used to, for example, test the
functions of the revolver head. 3
NOTE
Each of the max. 4 gantries can be addressed separately.
The functions are identical for all the gantries. 3
Gantry 2 F6 3
Single functions for Gantry 2 3
Gantry 3 Shift 5 3
Single functions for Gantry 3 3
Gantry 4 Shift 6 3
Single functions for Gantry 4 3
Conveyor 2 F7 3
Single functions for PCB conveyor 2 (= left conveyor track in the case of dual conveyors) 3
NOTE
The single functions for Conveyor 2 can only be called if a dual conveyor has been configured.
The functions are identical to the functions for Conveyor 1. 3
Conveyor 1 F8 3
This is used to call the single functions for PCB conveyor 1 (= right conveyor track in the case of
dual conveyors). These are used to test and set the functional modules for PCB conveyor as well
as to set the conveyor width. 3
3 Graphical user interface SIPLACE Software Guide SR.503.xx
3.3 User interface - views and menus Issue 12/01 EN
38
NOTE
The next two menu options belong to the group of vision functions.
These functions are used to teach and test fiducials, measure components and change compo-
nent package form data.
The vision functions cannot be executed at the „Operator“ access level. 3
Teach fiducial F9 3
This menu item is used to call the functions for the processing of fiducials for PCB position recog-
nition.
For a more extensive description of the procedure refer to the „Vision functions“ section of the op-
erating instructions. 3
Test component F10 3
This menu item is used to call the functions for the processing of component package forms for
component centering.
For a more extensive description of the procedure refer to the „Vision Functions“ section of the
operating instructions. 3
3
Start SITEST F11 3
This automatically starts the SITEST test program for machine set-up and calibration.
The user interface, together with the procedure for the execution of the functions, is described in
the separate User’s Manual for the SITEST test program. 3
NOTE
The SITEST test program cannot be started from the "Operator" access level. 3
GEM F12 3
This menu item is used to call the GEM interface functions. See Option „GEM Interface“ on page
97. 3
NOTE
The GEM interface functions cannot be called unless the interface has been configured.
At the „Operator“ access level, only the function „Send and receive messages“ is available. In the
„GEM State View“ function the buttons are inactive for the „Operator“. 3